Photon and proton therapy planning comparison for malignant glioma based on CT, FDG-PET, DTI-MRI and fiber tracking

Per Munck af Rosenschöld, Silke Engelholm, Lars Ohlhues, Ian Law, Ivan Vogelius, Svend Aage Engelholm

34 Citationer (Scopus)

Abstract

The purpose of this study was to compare treatment plans generated using fixed beam Intensity Modulated photon Radiation Therapy (IMRT), inversely optimized arc therapy (RapidArc(R), RA) with spot-scanned Intensity Modulated Proton Therapy (IMPT) for high-grade glioma patients. Plans were compared with respect to target coverage and sparing of organs at risk (OARs), with special attention to the possibility of hippocampus sparing.
OriginalsprogEngelsk
TidsskriftActa Oncologica
Vol/bind50
Udgave nummer6
Sider (fra-til)777-83
Antal sider7
ISSN0284-186X
DOI
StatusUdgivet - 2011

Fingeraftryk

Dyk ned i forskningsemnerne om 'Photon and proton therapy planning comparison for malignant glioma based on CT, FDG-PET, DTI-MRI and fiber tracking'. Sammen danner de et unikt fingeraftryk.