Pharmacokinetic Analysis of (64)Cu-ATSM Dynamic PET in Human Xenograft Tumors in Mice

Fan Li, Jesper Tranekjær Jørgensen, Jacob Madsen, Andreas Kjaer

1 Citationer (Scopus)

Abstract

UNLABELLED: The aim of this study was to evaluate the feasibility to perform voxel-wise kinetic modeling on datasets obtained from tumor-bearing mice that underwent dynamic PET scans with (64)Cu-ATSM and extract useful physiological parameters.

METHODS: Tumor-bearing mice underwent 90-min dynamic PET scans with (64)Cu-ATSM and CT scans with contrast. Irreversible and reversible two-tissue compartment models were fitted to time activity curves (TACs) obtained from whole tumor volumes and compared using the Akaike information criterion (AIC). Based on voxel-wise pharmacokinetic analysis, parametric maps of model rate constants k₁, k₃ and Ki were generated and compared to (64)Cu-ATSM uptake.

RESULTS: Based on the AIC, an irreversible two-tissue compartment model was selected for voxel-wise pharmacokinetic analysis. Of the extracted parameters, k₁ (~perfusion) showed a strong correlation with early tracer uptake (mean spearman R = 0.88) 5 min post injection (pi). Moreover, positive relationships were found between late tracer uptake (90 min pi) and both k₃ and the net influx rate constant, Ki (mean spearman R = 0.56 and R = 0.86; respectively).

CONCLUSION: This study shows the feasibility to extract relevant parameters from voxel-wise pharmacokinetic analysis to be used for preclinical validation of (64)Cu-ATSM as a hypoxia-specific PET tracer.

OriginalsprogEngelsk
TidsskriftDiagnostics
Vol/bind5
Udgave nummer2
Sider (fra-til)96-112
Antal sider17
ISSN2075-4418
DOI
StatusUdgivet - 2015

Fingeraftryk

Dyk ned i forskningsemnerne om 'Pharmacokinetic Analysis of (64)Cu-ATSM Dynamic PET in Human Xenograft Tumors in Mice'. Sammen danner de et unikt fingeraftryk.

Citationsformater