Spring til hovednavigation Spring til søgning Spring til hovedindhold

PET/MRI for Oncologic Brain Imaging: A Comparison of Standard MR-Based Attenuation Corrections with a Model-Based Approach for the Siemens mMR PET/MR System

  • Ivo Rausch
  • , Lucas Rischka
  • , Claes N Ladefoged
  • , Julia Furtner
  • , Matthias Fenchel
  • , Andreas Hahn
  • , Rupert Lanzenberger
  • , Marius E Mayerhoefer
  • , Tatjana Traub-Weidinger
  • , Thomas Beyer
27 Citationer (Scopus)

Abstract

The aim of this study was to compare attenuation-correction (AC) approaches for PET/MRI in clinical neurooncology.Methods:Forty-nine PET/MRI brain scans were included: brain tumor studies using18F-fluoro-ethyl-tyrosine (18F-FET) (n= 31) and68Ga-DOTANOC (n= 7) and studies of healthy subjects using18F-FDG (n= 11). For each subject, MR-based AC maps (MR-AC) were acquired using the standard DIXON- and ultrashort echo time (UTE)-based approaches. A third MR-AC was calculated using a model-based, postprocessing approach to account for bone attenuation values (BD, noncommercial prototype software by Siemens Healthcare). As a reference, AC maps were derived from patient-specific CT images (CTref). PET data were reconstructed using standard settings after AC with all 4 AC methods. We report changes in diagnosis for all brain tumor patients and the following relative differences values (RDs [%]), with regards to AC-CTref: for18F-FET (A)-SUVs as well as volumes of interest (VOIs) defined by a 70% threshold of all segmented lesions and lesion-to-background ratios; for68Ga-DOTANOC (B)-SUVs as well as VOIs defined by a 50% threshold for all lesions and the pituitary gland; and for18F-FDG (C)-RD of SUVs of the whole brain and 10 anatomic regions segmented on MR images.Results:For brain tumor imaging (A and B), the standard PET-based diagnosis was not affected by any of the 3 MR-AC methods. For A, the average RDs of SUVmeanwere -10%, -4%, and -3% and of the VOIs 1%, 2%, and 7% for DIXON, UTE, and BD, respectively. Lesion-to-background ratios for all MR-AC methods were similar to that of CTref. For B, average RDs of SUVmeanwere -11%, -11%, and -3% and of the VOIs 1%, -4%, and -3%, respectively. In the case of18F-FDG PET/MRI (C), RDs for the whole brain were -11%, -8%, and -5% for DIXON, UTE, and BD, respectively.Conclusion:The diagnostic reading of PET/MR patients with brain tumors did not change with the chosen AC method. Quantitative accuracy of SUVs was clinically acceptable for UTE- and BD-AC for group A, whereas for group B BD was in accordance with CTref. Nevertheless, for the quantification of individual lesions large deviations to CTref can be observed independent of the MR-AC method used.

OriginalsprogEngelsk
TidsskriftJournal of nuclear medicine : official publication, Society of Nuclear Medicine
Vol/bind58
Udgave nummer9
Sider (fra-til)1519-1525
Antal sider7
ISSN0161-5505
DOI
StatusUdgivet - sep. 2017

Fingeraftryk

Dyk ned i forskningsemnerne om 'PET/MRI for Oncologic Brain Imaging: A Comparison of Standard MR-Based Attenuation Corrections with a Model-Based Approach for the Siemens mMR PET/MR System'. Sammen danner de et unikt fingeraftryk.

Citationsformater