TY - JOUR
T1 - Patient-reported outcomes and complications of a new-generation total knee system
T2 - a randomized controlled trial
AU - Mortensen, Kristian R L
AU - Ingelsrud, Lina H
AU - Odgaard, Anders
AU - Kappel, Andreas
AU - Varnum, Claus
AU - Schrøder, Henrik
AU - Gromov, Kirill
AU - Troelsen, Anders
PY - 2025/2/25
Y1 - 2025/2/25
N2 - BACKGROUND AND PURPOSE: Documentation of new-generation implants' short-term performance could reassure surgeons and patients about their use, while awaiting the long-term outcome. Our aim was to compare the performance of a newer total knee arthroplasty (TKA) system with its predecessor, measured by patient-reported knee function, pain, and complication rate.METHODS: We performed a multi-center, randomized, controlled trial (clinicaltrials.gov ID: NCT03073941). 314 patients with primary osteoarthritis were randomized to treatment with a Persona or NexGen cruciate-retaining TKA system and followed for 2 years. The primary outcome was measured with the patient-reported outcome (PRO) Oxford Knee Score (OKS) 2 years post-surgery. Secondary outcomes were the OKS-Activity and Participation questionnaire (OKS-APQ), Forgotten Joint Score (FJS), EQ-5D-3L, and number of complications during the study period. Responder analyses were performed using Patient Acceptable Symptom State (PASS) and Minimal Important Change (MIC) criteria.RESULTS: Primary outcome was available from 289 patients (92%). We found no difference in adjusted mean OKS between the groups 2 years post-surgery (0.1, 95% confidence interval -1.4 to 1.7). We found no significant differences in adjusted mean of secondary PROs, PRO time-weighted averages, proportion of patients with PASS or MIC, or complications 2 years post-surgery.CONCLUSION: We found no difference in OKS 2 years post-surgery, or in any secondary variables analyzed including complications, between the 2 TKA systems. Short-term safety and performance of the Persona TKA was comparable to its predecessor.
AB - BACKGROUND AND PURPOSE: Documentation of new-generation implants' short-term performance could reassure surgeons and patients about their use, while awaiting the long-term outcome. Our aim was to compare the performance of a newer total knee arthroplasty (TKA) system with its predecessor, measured by patient-reported knee function, pain, and complication rate.METHODS: We performed a multi-center, randomized, controlled trial (clinicaltrials.gov ID: NCT03073941). 314 patients with primary osteoarthritis were randomized to treatment with a Persona or NexGen cruciate-retaining TKA system and followed for 2 years. The primary outcome was measured with the patient-reported outcome (PRO) Oxford Knee Score (OKS) 2 years post-surgery. Secondary outcomes were the OKS-Activity and Participation questionnaire (OKS-APQ), Forgotten Joint Score (FJS), EQ-5D-3L, and number of complications during the study period. Responder analyses were performed using Patient Acceptable Symptom State (PASS) and Minimal Important Change (MIC) criteria.RESULTS: Primary outcome was available from 289 patients (92%). We found no difference in adjusted mean OKS between the groups 2 years post-surgery (0.1, 95% confidence interval -1.4 to 1.7). We found no significant differences in adjusted mean of secondary PROs, PRO time-weighted averages, proportion of patients with PASS or MIC, or complications 2 years post-surgery.CONCLUSION: We found no difference in OKS 2 years post-surgery, or in any secondary variables analyzed including complications, between the 2 TKA systems. Short-term safety and performance of the Persona TKA was comparable to its predecessor.
KW - Humans
KW - Arthroplasty, Replacement, Knee/adverse effects
KW - Patient Reported Outcome Measures
KW - Male
KW - Female
KW - Aged
KW - Osteoarthritis, Knee/surgery
KW - Middle Aged
KW - Knee Prosthesis/adverse effects
KW - Postoperative Complications/etiology
KW - Prosthesis Design
KW - Treatment Outcome
UR - https://www.scopus.com/pages/publications/86000044480
U2 - 10.2340/17453674.2025.43004
DO - 10.2340/17453674.2025.43004
M3 - Journal article
C2 - 39998994
SN - 1745-3674
VL - 96
SP - 195
EP - 202
JO - Acta orthopaedica
JF - Acta orthopaedica
ER -