Abstract
In each femoral condyle of 8 Labrador dogs, a non weight-bearing hydroxyapatite-coated implant was inserted surrounded by a 3 mm gap. Each gap was filled with bone allograft or ProOsteon with or without OP-1 delivered in a bovine collagen type I carrier (OP-1 device). 300 microg OP-1 was used in the 0.75 cc gap surrounding the implant. After 3 weeks, the OP-1 device enhanced implant fixation by 800% (p
| Originalsprog | Engelsk |
|---|---|
| Tidsskrift | Acta Orthopaedica |
| Vol/bind | 73 |
| Udgave nummer | 1 |
| Sider (fra-til) | 31-9 |
| Antal sider | 9 |
| ISSN | 1745-3674 |
| DOI | |
| Status | Udgivet - 2002 |
| Udgivet eksternt | Ja |
Fingeraftryk
Dyk ned i forskningsemnerne om 'Osteogenic protein 1 device increases bone formation and bone graft resorption around cementless implants'. Sammen danner de et unikt fingeraftryk.Citationsformater
- APA
- Standard
- Harvard
- Vancouver
- Author
- BIBTEX
- RIS