Optimized MLAA for quantitative non-TOF PET/MR of the brain

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Simulating effects of brain atrophy in longitudinal PET imaging with an anthropomorphic brain phantom

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Repeated diffusion MRI reveals earliest time point for stratification of radiotherapy response in brain metastases

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Comment on: 'A Poisson resampling method for simulating reduced counts in nuclear medicine images'

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Risk-optimized proton therapy to minimize radiogenic second cancers

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Multi-site benchmarking of clinical 13C RF coils at 3T

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Guidelines for the content and format of PET brain data in publications and archives: A consensus paper

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Characteristics of patients with familial Mediterranean fever in Denmark: a retrospective nationwide register-based cohort study

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer

For quantitative tracer distribution in positron emission tomography, attenuation correction is essential. In a hybrid PET/CT system the CT images serve as a basis for generation of the attenuation map, but in PET/MR, the MR images do not have a similarly simple relationship with the attenuation map. Hence attenuation correction in PET/MR systems is more challenging. Typically either of two MR sequences are used: the Dixon or the ultra-short time echo (UTE) techniques. However these sequences have some well-known limitations. In this study, a reconstruction technique based on a modified and optimized non-TOF MLAA is proposed for PET/MR brain imaging. The idea is to tune the parameters of the MLTR applying some information from an attenuation image computed from the UTE sequences and a T1w MR image. In this MLTR algorithm, an [Formula: see text] parameter is introduced and optimized in order to drive the algorithm to a final attenuation map most consistent with the emission data. Because the non-TOF MLAA is used, a technique to reduce the cross-talk effect is proposed. In this study, the proposed algorithm is compared to the common reconstruction methods such as OSEM using a CT attenuation map, considered as the reference, and OSEM using the Dixon and UTE attenuation maps. To show the robustness and the reproducibility of the proposed algorithm, a set of 204 [(18)F]FDG patients, 35 [(11)C]PiB patients and 1 [(18)F]FET patient are used. The results show that by choosing an optimized value of [Formula: see text] in MLTR, the proposed algorithm improves the results compared to the standard MR-based attenuation correction methods (i.e. OSEM using the Dixon or the UTE attenuation maps), and the cross-talk and the scale problem are limited.

OriginalsprogEngelsk
TidsskriftPhysics in Medicine and Biology
Vol/bind61
Udgave nummer24
Sider (fra-til)8854-8874
Antal sider21
ISSN0031-9155
DOI
StatusUdgivet - 21 dec. 2016

ID: 49714650