TY - JOUR
T1 - Optic disc drusen in patients diagnosed with normal tension glaucoma
AU - Ahmadi, Hamid
AU - Fotesko, Kyrylo
AU - Ba-Ali, Shakoor
AU - Hamann, Steffen
AU - Kolko, Miriam
N1 - © 2022 The Authors. Acta Ophthalmologica published by John Wiley & Sons Ltd on behalf of Acta Ophthalmologica Scandinavica Foundation.
PY - 2023/5
Y1 - 2023/5
N2 - PURPOSE: To investigate the prevalence of optic disc drusen (ODD) and optic nerve head (ONH) morphology in patients diagnosed with normal tension glaucoma (NTG).METHODS: In this prospective cross-sectional study, we included patients diagnosed with NTG from two glaucoma units. In both eyes, dense enhanced depth imaging optical coherence tomography volume scans of the ONH by means of standardized scanning guidelines were performed to examine for presence of ODD, and radial ONH scans were used for investigating parameters such as scleral canal diameter, cup/disc ratio and cup depth.RESULTS: We found ODD in 7 (3.6%) of 195 eyes, in 6 (6.1%) out of 98 patients diagnosed with NTG. The ODD were not ophthalmoscopically visible in five out of six patients. Eyes with ODD had lower cup/disc ratio, 0.44 ± 0.4 (p = 0.040), and less-prominent cup depth, 236.6 ± 204.4 μm (p = 0.041) compared to eyes without ODD, 0.81 ± 0.2 and 437.8 ± 139.1 μm, respectively. We found no significant difference in scleral canal diameter between the eyes without (1602.8 ± 193 μm) and those with ODD (1492 ± 123.4 μm, p = 0.057).CONCLUSION: The prevalence of ODD in patients diagnosed with NTG is substantially higher than in the background population. A low cup/disc ratio correlates with ODD presence. Therefore, due to the challenges associated with NTG diagnosis, we recommend examining the deep layers of the ONH in NTG patients with a cup/disc ratio lower than 0.5 to avoid misdiagnosing ODD as NTG.
AB - PURPOSE: To investigate the prevalence of optic disc drusen (ODD) and optic nerve head (ONH) morphology in patients diagnosed with normal tension glaucoma (NTG).METHODS: In this prospective cross-sectional study, we included patients diagnosed with NTG from two glaucoma units. In both eyes, dense enhanced depth imaging optical coherence tomography volume scans of the ONH by means of standardized scanning guidelines were performed to examine for presence of ODD, and radial ONH scans were used for investigating parameters such as scleral canal diameter, cup/disc ratio and cup depth.RESULTS: We found ODD in 7 (3.6%) of 195 eyes, in 6 (6.1%) out of 98 patients diagnosed with NTG. The ODD were not ophthalmoscopically visible in five out of six patients. Eyes with ODD had lower cup/disc ratio, 0.44 ± 0.4 (p = 0.040), and less-prominent cup depth, 236.6 ± 204.4 μm (p = 0.041) compared to eyes without ODD, 0.81 ± 0.2 and 437.8 ± 139.1 μm, respectively. We found no significant difference in scleral canal diameter between the eyes without (1602.8 ± 193 μm) and those with ODD (1492 ± 123.4 μm, p = 0.057).CONCLUSION: The prevalence of ODD in patients diagnosed with NTG is substantially higher than in the background population. A low cup/disc ratio correlates with ODD presence. Therefore, due to the challenges associated with NTG diagnosis, we recommend examining the deep layers of the ONH in NTG patients with a cup/disc ratio lower than 0.5 to avoid misdiagnosing ODD as NTG.
KW - Cross-Sectional Studies
KW - Humans
KW - Intraocular Pressure
KW - Low Tension Glaucoma/diagnosis
KW - Optic Disk
KW - Optic Disk Drusen/diagnosis
KW - Prospective Studies
KW - Tomography, Optical Coherence
KW - optic disc drusen
KW - optical coherence tomography
KW - optic nerve head drusen
KW - optic neuropathies
KW - normal tension glaucoma
UR - https://www.scopus.com/pages/publications/85142126505
U2 - 10.1111/aos.15286
DO - 10.1111/aos.15286
M3 - Journal article
C2 - 36373859
SN - 1755-375X
VL - 101
SP - 277
EP - 284
JO - Acta Ophthalmologica
JF - Acta Ophthalmologica
IS - 3
ER -