Noninvasive Estimation of Pressure Changes Using 2-D Vector Velocity Ultrasound: An Experimental Study With In Vivo Examples

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. Portable Vector Flow Imaging Compared with Spectral Doppler Ultrasonography

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Automatic Detection of B-lines in In-Vivo Lung Ultrasound

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Real-Time 2-D Phased Array Vector Flow Imaging

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. A Vector Flow Imaging Method for Portable Ultrasound Using Synthetic Aperture Sequential Beamforming

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  5. Fast Plane Wave 2-D Vector Flow Imaging Using Transverse Oscillation and Directional Beamforming

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Gastrointestinal Applications of Iodine Quantification Using Dual-Energy CT: A Systematic Review

    Publikation: Bidrag til tidsskriftReviewForskningpeer review

  2. Flow Complexity Estimation in Dysfunctional Arteriovenous Dialysis Fistulas using Vector Flow Imaging

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Postembolization Syndrome after Prostatic Artery Embolization: A Systematic Review

    Publikation: Bidrag til tidsskriftReviewForskningpeer review

Vis graf over relationer

A noninvasive method for estimating intravascular pressure changes using 2-D vector velocity is presented. The method was first validated on computational fluid dynamic (CFD) data and with catheter measurements on phantoms. Hereafter, the method was tested in vivo at the carotid bifurcation and at the aortic valve of two healthy volunteers. Ultrasound measurements were performed using the experimental scanner SARUS, in combination with an 8 MHz linear array transducer for experimental scans and a carotid scan, whereas a 3.5-MHz phased array probe was employed for a scan of an aortic valve. Measured 2-D fields of angle-independent vector velocities were obtained using synthetic aperture imaging. Pressure drops from simulated steady flow through six vessel geometries spanning different degrees of diameter narrowing, running from 20%-70%, showed relative biases from 0.35% to 12.06%, depending on the degree of constriction. Phantom measurements were performed on a vessel with the same geometry as the 70% constricted CFD model. The derived pressure drops were compared to pressure drops measured by a clinically used 4F catheter and to a finite-element model. The proposed method showed peak systolic pressure drops of -3 kPa ± 57 Pa, while the catheter and the simulation model showed -5.4 kPa ± 52 Pa and -2.9 kPa, respectively. An in vivo acquisition of 10 s was made at the carotid bifurcation. This produced eight cardiac cycles from where pressure gradients of -227 ± 15 Pa were found. Finally, the aortic valve measurement showed a peak pressure drop of -2.1 kPa over one cardiac cycle. In conclusion, pressure gradients from convective flow changes are detectable using 2-D vector velocity ultrasound.

OriginalsprogEngelsk
TidsskriftIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Vol/bind65
Udgave nummer5
Sider (fra-til)709-719
Antal sider11
ISSN0885-3010
DOI
StatusUdgivet - maj 2018

ID: 55235865