TY - JOUR
T1 - Non-invasive measurement techniques for quantitative assessment of optic nerve head blood flow
AU - Vosborg, Fia
AU - Malmqvist, Lasse
AU - Hamann, Steffen
PY - 2020/3
Y1 - 2020/3
N2 - Diseases of the optic nerve head involving changes in blood flow are common. However, the pathophysiology is not always fully understood. Several non-invasive methods for measuring optic nerve head blood flow are available, but currently no gold standard has been established. Methods for measuring blood flow in optic neuropathies including colour Doppler imaging, retinal function imager, optical coherence tomography angiography and laser speckle flowgraphy are reviewed. Ultrasound colour Doppler imaging is a fast measurement technique where several different parameters, especially the blood flow velocity, can be calculated. Though used for many years in ophthalmology, its use is not standardized and it requires significant observer skills. The retinal function imager is a direct method where the haemoglobin in erythrocytes is visualized and blood flow velocities in retinal vessels are calculated from a series of photos. The technique is not suitable for direct measurement of blood flow within the optic nerve head. Laser speckle flowgraphy uses a laser light which creates a light scatter pattern in the tissue. Particles moving in the area causes changes in the speckle pattern from which a relative blood flow can be estimated. It is, however, not known whether optic nerve head microcirculation is measurable with the technique. Optical coherence tomography angiography uses multiple scans to evaluate blood flow with good reproducibility but often problems with artefacts. The technique is continuously being refined and increasingly used in research as a tool for the study of blood flow in retinopathies and optic neuropathies. Most of the conducted studies are based on small sample sizes, but some of the methods show promising results in an optic nerve head blood flow research setting. Further and larger studies are required to provide standardized and comparable measurements before one or more of the methods can be considered clinical helpful in daily practice.
AB - Diseases of the optic nerve head involving changes in blood flow are common. However, the pathophysiology is not always fully understood. Several non-invasive methods for measuring optic nerve head blood flow are available, but currently no gold standard has been established. Methods for measuring blood flow in optic neuropathies including colour Doppler imaging, retinal function imager, optical coherence tomography angiography and laser speckle flowgraphy are reviewed. Ultrasound colour Doppler imaging is a fast measurement technique where several different parameters, especially the blood flow velocity, can be calculated. Though used for many years in ophthalmology, its use is not standardized and it requires significant observer skills. The retinal function imager is a direct method where the haemoglobin in erythrocytes is visualized and blood flow velocities in retinal vessels are calculated from a series of photos. The technique is not suitable for direct measurement of blood flow within the optic nerve head. Laser speckle flowgraphy uses a laser light which creates a light scatter pattern in the tissue. Particles moving in the area causes changes in the speckle pattern from which a relative blood flow can be estimated. It is, however, not known whether optic nerve head microcirculation is measurable with the technique. Optical coherence tomography angiography uses multiple scans to evaluate blood flow with good reproducibility but often problems with artefacts. The technique is continuously being refined and increasingly used in research as a tool for the study of blood flow in retinopathies and optic neuropathies. Most of the conducted studies are based on small sample sizes, but some of the methods show promising results in an optic nerve head blood flow research setting. Further and larger studies are required to provide standardized and comparable measurements before one or more of the methods can be considered clinical helpful in daily practice.
KW - Blood Flow Velocity/physiology
KW - Diagnostic Techniques, Ophthalmological
KW - Humans
KW - Laser-Doppler Flowmetry/methods
KW - Optic Disk/blood supply
KW - Regional Blood Flow/physiology
KW - Reproducibility of Results
KW - Retinal Diseases/diagnostic imaging
KW - Retinal Vessels/diagnostic imaging
KW - Tomography, Optical Coherence/methods
U2 - 10.1177/1120672119858891
DO - 10.1177/1120672119858891
M3 - Review
C2 - 31242750
SN - 1120-6721
VL - 30
SP - 235
EP - 244
JO - European Journal of Ophthalmology
JF - European Journal of Ophthalmology
IS - 2
ER -