Abstract
Abstract
Continuous glucose monitoring enables innovative insulin pumps to stop infusion of insulin at selected blood glucose thresholds. We present the first and successful Danish clinical case using this device, a Medtronics Veo insulin pump, in a patient with numerous cases of severe hypoglycaemia during earlier pregnancies. During this treatment insulin infusion was frequently stopped and severe hypoglycaemia prevented in the remaining part of pregnancy
Continuous glucose monitoring enables innovative insulin pumps to stop infusion of insulin at selected blood glucose thresholds. We present the first and successful Danish clinical case using this device, a Medtronics Veo insulin pump, in a patient with numerous cases of severe hypoglycaemia during earlier pregnancies. During this treatment insulin infusion was frequently stopped and severe hypoglycaemia prevented in the remaining part of pregnancy
| Bidragets oversatte titel | New innovative glucose-controlled pump enabling glucose control in a pregnant patient with diabetes. |
|---|---|
| Originalsprog | Dansk |
| Artikelnummer | V07120401. |
| Tidsskrift | Ugeskrift for Laeger |
| Vol/bind | 176 |
| Udgave nummer | 25A |
| Sider (fra-til) | 76-77 |
| ISSN | 0041-5782 |
| Status | Udgivet - 15 dec. 2014 |