TY - JOUR
T1 - Myocardial fibrosis and the effect of primary prophylactic defibrillator implantation in patients with non-ischemic systolic heart failure-DANISH-MRI
AU - Elming, Marie Bayer
AU - Hammer-Hansen, Sophia
AU - Voges, Inga
AU - Nyktari, Eva
AU - Raja, Anna Axelsson
AU - Svendsen, Jesper Hastrup
AU - Pehrson, Steen
AU - Signorovitch, James
AU - Køber, Lars
AU - Prasad, Sanjay K
AU - Thune, Jens Jakob
N1 - Copyright © 2019 Elsevier Inc. All rights reserved.
PY - 2020/3
Y1 - 2020/3
N2 - AIMS: Patients with non-ischemic systolic heart failure have an increased risk of sudden cardiac death (SCD). Myocardial fibrosis, detected as late gadolinium enhancement (LGE) with cardiac magnetic resonance (CMR), has been shown to predict all-cause mortality. We hypothesized that LGE can identify patients with non-ischemic heart failure who will benefit from ICD implantation.METHODS AND RESULTS: In this prospective observational sub-study of the Danish Study to Assess the Efficacy of ICDs in Patients with Nonischemic Systolic Heart Failure on Mortality (DANISH), 252 patients underwent CMR. LGE was quantified by the full width/half maximum method. The primary endpoint was all-cause mortality. LGE could be adequately assessed in 236 patients, median age was 61 years and median duration of heart failure was 14 months; there were 108 patients (46%) randomized to ICD. Median follow-up time was 5.3 years. Median left ventricular ejection fraction on CMR was 35%. In all, 50 patients died. LGE was present in 113 patients (48%). The presence of LGE was an independent predictor of all-cause mortality (HR 1.82; 95% CI 1.002-3.29; P = .049) after adjusting for known cardiovascular risk factors. ICD implantation did not impact all-cause mortality, for either patients with LGE (HR 1.18; 95% CI 0.59-2.38; P = .63), or for patients without LGE (HR 1.00; 95% CI 0.39-2.53; P = .99), (P for interaction =0.79).CONCLUSION: In patients with non-ischemic systolic heart failure, LGE predicted all-cause mortality. However, in this cohort, LGE did not identify a group of patients who survived longer by receiving an ICD.
AB - AIMS: Patients with non-ischemic systolic heart failure have an increased risk of sudden cardiac death (SCD). Myocardial fibrosis, detected as late gadolinium enhancement (LGE) with cardiac magnetic resonance (CMR), has been shown to predict all-cause mortality. We hypothesized that LGE can identify patients with non-ischemic heart failure who will benefit from ICD implantation.METHODS AND RESULTS: In this prospective observational sub-study of the Danish Study to Assess the Efficacy of ICDs in Patients with Nonischemic Systolic Heart Failure on Mortality (DANISH), 252 patients underwent CMR. LGE was quantified by the full width/half maximum method. The primary endpoint was all-cause mortality. LGE could be adequately assessed in 236 patients, median age was 61 years and median duration of heart failure was 14 months; there were 108 patients (46%) randomized to ICD. Median follow-up time was 5.3 years. Median left ventricular ejection fraction on CMR was 35%. In all, 50 patients died. LGE was present in 113 patients (48%). The presence of LGE was an independent predictor of all-cause mortality (HR 1.82; 95% CI 1.002-3.29; P = .049) after adjusting for known cardiovascular risk factors. ICD implantation did not impact all-cause mortality, for either patients with LGE (HR 1.18; 95% CI 0.59-2.38; P = .63), or for patients without LGE (HR 1.00; 95% CI 0.39-2.53; P = .99), (P for interaction =0.79).CONCLUSION: In patients with non-ischemic systolic heart failure, LGE predicted all-cause mortality. However, in this cohort, LGE did not identify a group of patients who survived longer by receiving an ICD.
U2 - 10.1016/j.ahj.2019.10.020
DO - 10.1016/j.ahj.2019.10.020
M3 - Journal article
C2 - 31955812
SN - 0002-8703
VL - 221
SP - 165
EP - 176
JO - American Heart Journal
JF - American Heart Journal
ER -