Forskning
Udskriv Udskriv
Switch language
Region Hovedstaden - en del af Københavns Universitetshospital
Udgivet

Multidimensional LC-MS/MS enables simultaneous quantification of intact human insulin and five recombinant analogs in human plasma

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. Peptide disc mediated control of membrane protein orientation in supported lipid bilayers for surface-sensitive investigations

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Direct Monitoring of Exogenous γ-Hydroxybutyric Acid in Body Fluids by NMR Spectroscopy

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Electrochemical reduction of disulfide-containing proteins for hydrogen/deuterium exchange monitored by mass spectrometry

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer

This work provides a multidimensional method for the simultaneous, direct quantification of intact human insulin and five insulin analogs in human plasma. This investigation solves both the selectivity and sensitivity problems encountered for accurate quantification of insulins in plasma since the former is not possible with conventional assays and the latter with conventional LC-MS/MS. The method uses a mixed-mode SPE and a multidimensional LC method including a solid-core particle column containing an anion exchange stationary phase. Matrix factors for all analogs were calculated in 6 sources of human plasma and CVs of the matrix factors were <15% in all cases supporting the selectivity of the method, while achieving LLOQs of 50-200 pg/mL (1.4-5.6 μIU/mL) for each insulin from 250 μL of human plasma. The average accuracy for the standard curve points in extracted human plasma was 99-100%. Average inter- and intraday accuracies for QC samples were 98% and 94%, respectively. Average inter- and intraday precisions for QC samples were 7.5 and 5.3%, respectively. Patient samples were analyzed in a blind study and results concurred with their diabetes multidosing regimes. The study also demonstrated that the presence of high levels of human insulin and bovine insulin does not interfere with quantification of any of the analyzed analogs. We propose this method for the accurate pharmacokinetic monitoring of diabetic patients, for sport antidoping and forensic toxicology analysis.

OriginalsprogEngelsk
TidsskriftAnalytical Chemistry
Vol/bind86
Udgave nummer1
Sider (fra-til)694-702
Antal sider9
ISSN0003-2700
DOI
StatusUdgivet - 7 jan. 2014
Eksternt udgivetJa

ID: 54960798