Mitral and aortic valvular flow: quantification with MR phase mapping.

Publikation: Bidrag til tidsskriftTidsskriftartikelForskning

  1. Tractography reproducibility challenge with empirical data (TraCED): The 2017 ISMRM diffusion study group challenge

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Comparison of four MRI protocols for detection of extrahepatic colorectal cancer metastases

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Brain capillary transit time heterogeneity in healthy volunteers measured by dynamic contrast-enhanced T1 -weighted perfusion MRI

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Comparison of global cerebral blood flow measured by phase-contrast mapping MRI with (15) O-H2 O positron emission tomography

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Prevalence of cerebral and pulmonary thrombosis in patients with cyanotic congenital heart disease

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Percutaneous left atrial appendage occlusion for stroke prevention in atrial fibrillation: an update

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Temporal changes in suicide rates for persons treated and not treated with antidepressants in Denmark during 1995-1999

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Left Ventricular Dimensions and Systolic Function in Obesity.

    Publikation: KonferencebidragKonferenceabstrakt til konferenceForskning

Vis graf over relationer
When magnetic resonance phase mapping is used to quantitate valvular blood flow, the presence of higher-order-motion terms may cause a loss of phase information. To overcome this problem, a sequence with reduced encoding for higher-order motion was used, achieved by decreasing the duration of the flow-encoding gradient to 2.2 msec. Tested on a flow phantom simulating a severe valvular stenosis, the sequence was found to be robust for higher-order motion within the clinical velocity range. In eight healthy volunteers, mitral and aortic volume flow rates and peak velocities were quantified by means of phase mapping and compared with results of the indicator-dilution technique and Doppler echocardiography, respectively. Statistically significant correlations were found between phase mapping and the other two techniques. Similar studies in patients with valvular disease indicate that phase mapping is also valid for pathologic conditions. Phase mapping may be used as a noninvasive clinical tool for flow quantification in heart valve disease.
Bidragets oversatte titelMitral and aortic valvular flow: quantification with MR phase mapping.