Measuring motion-induced B0 -fluctuations in the brain using field probes

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Harvard

Andersen, M, Hanson, LG, Madsen, KH, Wezel, J, Boer, V, van der Velden, T, van Osch, MJP, Klomp, D, Webb, AG & Versluis, MJ 2016, 'Measuring motion-induced B0 -fluctuations in the brain using field probes' Magnetic Resonance in Medicine, bind 75, nr. 5, s. 2020-2030. https://doi.org/10.1002/mrm.25802

APA

CBE

MLA

Vancouver

Author

Andersen, Mads ; Hanson, Lars G ; Madsen, Kristoffer H ; Wezel, Joep ; Boer, Vincent ; van der Velden, Tijl ; van Osch, Matthias J P ; Klomp, Dennis ; Webb, Andrew G ; Versluis, Maarten J. / Measuring motion-induced B0 -fluctuations in the brain using field probes. I: Magnetic Resonance in Medicine. 2016 ; Bind 75, Nr. 5. s. 2020-2030.

Bibtex

@article{608ab1b2f2454ac988fd3b81b45c4857,
title = "Measuring motion-induced B0 -fluctuations in the brain using field probes",
abstract = "PURPOSE: Fluctuations of the background magnetic field (B0 ) due to body and breathing motion can lead to significant artifacts in brain imaging at ultrahigh field. Corrections based on real-time sensing using external field probes show great potential. This study evaluates different aspects of field interpolation from these probes into the brain which is implicit in such methods. Measurements and simulations were performed to quantify how well B0 -fluctuations in the brain due to body and breathing motion are reflected in external field probe measurements.METHODS: Field probe measurements were compared with scanner acquired B0 -maps from experiments with breathing and shoulder movements. A realistic simulation of B0 -fluctuations caused by breathing was performed, and used for testing different sets of field probe positions.RESULTS: The B0 -fluctuations were well reflected in the field probe measurements in the shoulder experiments, while the breathing experiments showed only moderate correspondence. The simulations showed the importance of the probe positions, and that performing full 3(rd) order corrections based on 16 field probes is not recommended.CONCLUSION: Methods for quantitative assessment of the field interpolation problem were developed and demonstrated. Field corrections based on external field measurements show great potential, although potential pitfalls were identified. Magn Reson Med, 2015. {\circledC} 2015 Wiley Periodicals, Inc.",
author = "Mads Andersen and Hanson, {Lars G} and Madsen, {Kristoffer H} and Joep Wezel and Vincent Boer and {van der Velden}, Tijl and {van Osch}, {Matthias J P} and Dennis Klomp and Webb, {Andrew G} and Versluis, {Maarten J}",
note = "Published online June 15",
year = "2016",
month = "5",
doi = "10.1002/mrm.25802",
language = "English",
volume = "75",
pages = "2020--2030",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John/Wiley & Sons, Inc. John/Wiley & Sons Ltd",
number = "5",

}

RIS

TY - JOUR

T1 - Measuring motion-induced B0 -fluctuations in the brain using field probes

AU - Andersen, Mads

AU - Hanson, Lars G

AU - Madsen, Kristoffer H

AU - Wezel, Joep

AU - Boer, Vincent

AU - van der Velden, Tijl

AU - van Osch, Matthias J P

AU - Klomp, Dennis

AU - Webb, Andrew G

AU - Versluis, Maarten J

N1 - Published online June 15

PY - 2016/5

Y1 - 2016/5

N2 - PURPOSE: Fluctuations of the background magnetic field (B0 ) due to body and breathing motion can lead to significant artifacts in brain imaging at ultrahigh field. Corrections based on real-time sensing using external field probes show great potential. This study evaluates different aspects of field interpolation from these probes into the brain which is implicit in such methods. Measurements and simulations were performed to quantify how well B0 -fluctuations in the brain due to body and breathing motion are reflected in external field probe measurements.METHODS: Field probe measurements were compared with scanner acquired B0 -maps from experiments with breathing and shoulder movements. A realistic simulation of B0 -fluctuations caused by breathing was performed, and used for testing different sets of field probe positions.RESULTS: The B0 -fluctuations were well reflected in the field probe measurements in the shoulder experiments, while the breathing experiments showed only moderate correspondence. The simulations showed the importance of the probe positions, and that performing full 3(rd) order corrections based on 16 field probes is not recommended.CONCLUSION: Methods for quantitative assessment of the field interpolation problem were developed and demonstrated. Field corrections based on external field measurements show great potential, although potential pitfalls were identified. Magn Reson Med, 2015. © 2015 Wiley Periodicals, Inc.

AB - PURPOSE: Fluctuations of the background magnetic field (B0 ) due to body and breathing motion can lead to significant artifacts in brain imaging at ultrahigh field. Corrections based on real-time sensing using external field probes show great potential. This study evaluates different aspects of field interpolation from these probes into the brain which is implicit in such methods. Measurements and simulations were performed to quantify how well B0 -fluctuations in the brain due to body and breathing motion are reflected in external field probe measurements.METHODS: Field probe measurements were compared with scanner acquired B0 -maps from experiments with breathing and shoulder movements. A realistic simulation of B0 -fluctuations caused by breathing was performed, and used for testing different sets of field probe positions.RESULTS: The B0 -fluctuations were well reflected in the field probe measurements in the shoulder experiments, while the breathing experiments showed only moderate correspondence. The simulations showed the importance of the probe positions, and that performing full 3(rd) order corrections based on 16 field probes is not recommended.CONCLUSION: Methods for quantitative assessment of the field interpolation problem were developed and demonstrated. Field corrections based on external field measurements show great potential, although potential pitfalls were identified. Magn Reson Med, 2015. © 2015 Wiley Periodicals, Inc.

U2 - 10.1002/mrm.25802

DO - 10.1002/mrm.25802

M3 - Journal article

VL - 75

SP - 2020

EP - 2030

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 5

ER -

ID: 45444817