Forskning
Udskriv Udskriv
Switch language
Region Hovedstaden - en del af Københavns Universitetshospital
Udgivet

Measuring motion-induced B0 -fluctuations in the brain using field probes

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. ActiveAxADD: Toward non-parametric and orientationally invariant axon diameter distribution mapping using PGSE

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Quantification of cerebral perfusion and cerebrovascular reserve using Turbo-QUASAR arterial spin labeling MRI

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Coil profile estimation strategies for parallel imaging with hyperpolarized 13 C MRI

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Gamma-aminobutyric acid edited echo-planar spectroscopic imaging (EPSI) with MEGA-sLASER at 7T

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  5. Comparison of prospective head motion correction with NMR field probes and an optical tracking system

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Probing Context-Dependent Modulations of Ipsilateral Premotor-Motor Connectivity in Relapsing-Remitting Multiple Sclerosis

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Brain Changes Induced by Electroconvulsive Therapy Are Broadly Distributed

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Identifying Schizo-Obsessive Comorbidity by Tract-Based Spatial Statistics and Probabilistic Tractography

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer
Purpose: Fluctuations of the background magnetic field (B0)
due to body and breathing motion can lead to significant artifacts
in brain imaging at ultrahigh field. Corrections based on
real-time sensing using external field probes show great
potential. This study evaluates different aspects of field interpolation
from these probes into the brain which is implicit in
such methods. Measurements and simulations were performed
to quantify how well B0-fluctuations in the brain due to
body and breathing motion are reflected in external field probe
measurements.
Methods: Field probe measurements were compared with
scanner acquired B0-maps from experiments with breathing
and shoulder movements. A realistic simulation of B0-fluctuations
caused by breathing was performed, and used for testing
different sets of field probe positions.
Results: The B0-fluctuations were well reflected in the field
probe measurements in the shoulder experiments, while the
breathing experiments showed only moderate correspondence.
The simulations showed the importance of the probe
positions, and that performing full 3rd order corrections based
on 16 field probes is not recommended.
Conclusion: Methods for quantitative assessment of the field
interpolation problem were developed and demonstrated. Field
corrections based on external field measurements show great
potential, although potential pitfalls were identified.
OriginalsprogEngelsk
TidsskriftMagnetic Resonance in Medicine
Vol/bind75
Udgave nummer5
Sider (fra-til)2020-2030
Antal sider11
ISSN0740-3194
DOI
StatusUdgivet - maj 2016

Bibliografisk note

Published online June 15

ID: 45444817