Measuring motion-induced B0 -fluctuations in the brain using field probes

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. Improved calculation of the equilibrium magnetization of arterial blood in arterial spin labeling

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Sensitivity analysis of magnetic field measurements for magnetic resonance electrical impedance tomography (MREIT)

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Effects of imaging gradients in sequences with varying longitudinal storage time-Case of diffusion exchange imaging

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Dual-volume excitation and parallel reconstruction for J-difference-edited MR spectroscopy

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  5. Conventions and nomenclature for double diffusion encoding NMR and MRI

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Perspectives on Machine Learning for Classification of Schizotypy Using fMRI Data

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Volume of the Human Hippocampus and Clinical Response Following Electroconvulsive Therapy

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Development of a Symmetric Echo-Planar Spectroscopy Imaging Framework for Hyperpolarized 13C Imaging in a Clinical PET/MR Scanner

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Automatic skull segmentation from MR images for realistic volume conductor models of the head: Assessment of the state-of-the-art

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer
Purpose: Fluctuations of the background magnetic field (B0)
due to body and breathing motion can lead to significant artifacts
in brain imaging at ultrahigh field. Corrections based on
real-time sensing using external field probes show great
potential. This study evaluates different aspects of field interpolation
from these probes into the brain which is implicit in
such methods. Measurements and simulations were performed
to quantify how well B0-fluctuations in the brain due to
body and breathing motion are reflected in external field probe
measurements.
Methods: Field probe measurements were compared with
scanner acquired B0-maps from experiments with breathing
and shoulder movements. A realistic simulation of B0-fluctuations
caused by breathing was performed, and used for testing
different sets of field probe positions.
Results: The B0-fluctuations were well reflected in the field
probe measurements in the shoulder experiments, while the
breathing experiments showed only moderate correspondence.
The simulations showed the importance of the probe
positions, and that performing full 3rd order corrections based
on 16 field probes is not recommended.
Conclusion: Methods for quantitative assessment of the field
interpolation problem were developed and demonstrated. Field
corrections based on external field measurements show great
potential, although potential pitfalls were identified.
OriginalsprogEngelsk
TidsskriftMagnetic Resonance in Medicine
Vol/bind75
Tidsskriftsnummer5
Sider (fra-til)2020-2030
Antal sider11
ISSN0740-3194
DOI
StatusUdgivet - maj 2016

Bibliografisk note

Published online June 15

ID: 45444817