Measurement of digital blood pressure after local cooling

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Ultrasound-based speckle-tracking in tendons: a critical analysis for the technician and the clinician

    Publikation: Bidrag til tidsskriftReviewForskningpeer review

  2. Physiological responses of human skeletal muscle to acute blood flow restricted exercise assessed by multimodal MRI

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Reply to Dutheil et al

    Publikation: Bidrag til tidsskriftLetterForskningpeer review

  1. Dopamine D(2) receptor quantification in extrastriatal brain regions using [(123)I]epidepride with bolus/infusion

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Vestibularis-schwannomers diagnostik og vaekst bedømt ved SPECT kombineret med TL-201 Thallium

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Activation-induced resetting of cerebral oxygen and glucose uptake in the rat

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Activation-induced resetting of cerebral oxygen and glucose uptak in the rat

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  5. SPECT og PET i neurobiologien

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer
A double-inlet plastic cuff was designed for local cooling and systolic blood pressure measurement on the middle phalanx of the fingers. With a tourniquet on the proximal phalanx of one finger, cooling for 5 min made the digital artery temperature equal the skin temperature. The difference between the systolic pressure in a control finger and in the cooled finger give the reopening pressure in the digital arteries. At 30, 25, 20, 15, and 10 degrees C, respectively the percent decrease of the finger pressure was 0.2 (0.2), 1.5 (2.5), 8.5 (3.7), 11.4 (3.4), and 15.3 (3.1) in normal young women. In patients with primary or secondary Raynaud's phenomenon, the arterial tone showed an abrupt increase that most often led to complete closure of the digital arteries. The pathological response was expressed as an increased threshold temperature or a well-defined closing temperature that showed only small variations during standardized conditions.
OriginalsprogEngelsk
TidsskriftJournal of applied physiology: respiratory, environmental and exercise physiology
Vol/bind43
Udgave nummer5
Sider (fra-til)907-10
Antal sider4
ISSN0161-7567
StatusUdgivet - nov. 1977

ID: 39052956