TY - JOUR
T1 - Low restenosis rate of the NIR coronary stent
T2 - results of the Danish multicenter stent study (DANSTENT)--a randomized trial comparing a first-generation stent with a second-generation stent
AU - Jørgensen, Erik
AU - Kelbaek, Henning
AU - Helqvist, Steffen
AU - Jensen, Gunnar V H
AU - Saunamäki, Kari
AU - Kastrup, Jens
AU - Madsen, Jan Kyst
AU - Kløvgaard, Lene
AU - Thuesen, Leif
AU - Villadsen, Anton
AU - van Weert, Anton W M
AU - Reiber, Johan H C
AU - Danish multicenter stent study (DANSTENT)
PY - 2003/2
Y1 - 2003/2
N2 - BACKGROUND: Larger studies evaluating the angiographic results of second-generation stents are scarce. The objectives of this study were to assess current standards of angiographic and clinical outcomes after implantation of the second-generation stainless steel stent, NIR (Medinol Ltd, Tel Aviv, Israel), and to compare the outcomes with those of the first-generation Palmaz-Schatz (PS) stent (Johnson & Johnson, Warren, NJ).METHODS: Patients having coronary artery lesions that could be covered by a stent of 15 mm in length were randomly assigned to receive the NIR or the PS. Procedural success, 6-month angiographic findings, and 1-year clinical outcomes were determined.RESULTS: In 424 patients included in the study, the overall procedural success rate was high (NIR 98%, PS 99%, P =.90). Follow-up angiography was conducted in 91% of the patients. The overall rate of angiographic restenosis was low in both groups (NIR 9.9%, PS 12.6%, P =.35). We found a low restenosis rate in vessels with a minimal lumen diameter >3.1 mm after the procedure, particularly in the NIR group (<6%). The rate of target lesion revascularization after 1 year did not differ (NIR 12%, PS 10%, P =.47).CONCLUSIONS: The angiographic and clinical outcomes after implantation of the second-generation stainless steel stent were not significantly better than those of the first-generation stent. The low restenosis rates, particularly in patients with the largest minimal lumen diameters after stent implantation, warrants circumspection when planning the evaluation of newer stent technologies that aim to further reduce coronary restenosis.
AB - BACKGROUND: Larger studies evaluating the angiographic results of second-generation stents are scarce. The objectives of this study were to assess current standards of angiographic and clinical outcomes after implantation of the second-generation stainless steel stent, NIR (Medinol Ltd, Tel Aviv, Israel), and to compare the outcomes with those of the first-generation Palmaz-Schatz (PS) stent (Johnson & Johnson, Warren, NJ).METHODS: Patients having coronary artery lesions that could be covered by a stent of 15 mm in length were randomly assigned to receive the NIR or the PS. Procedural success, 6-month angiographic findings, and 1-year clinical outcomes were determined.RESULTS: In 424 patients included in the study, the overall procedural success rate was high (NIR 98%, PS 99%, P =.90). Follow-up angiography was conducted in 91% of the patients. The overall rate of angiographic restenosis was low in both groups (NIR 9.9%, PS 12.6%, P =.35). We found a low restenosis rate in vessels with a minimal lumen diameter >3.1 mm after the procedure, particularly in the NIR group (<6%). The rate of target lesion revascularization after 1 year did not differ (NIR 12%, PS 10%, P =.47).CONCLUSIONS: The angiographic and clinical outcomes after implantation of the second-generation stainless steel stent were not significantly better than those of the first-generation stent. The low restenosis rates, particularly in patients with the largest minimal lumen diameters after stent implantation, warrants circumspection when planning the evaluation of newer stent technologies that aim to further reduce coronary restenosis.
KW - Angina Pectoris/diagnostic imaging
KW - Angina, Unstable/diagnostic imaging
KW - Angioplasty, Balloon, Coronary
KW - Coronary Angiography
KW - Coronary Restenosis/diagnostic imaging
KW - Denmark
KW - Female
KW - Humans
KW - Male
KW - Middle Aged
KW - Multivariate Analysis
KW - Myocardial Ischemia/diagnostic imaging
KW - Odds Ratio
KW - Stents
U2 - 10.1067/mhj.2003.32
DO - 10.1067/mhj.2003.32
M3 - Journal article
C2 - 12595860
SN - 0002-8703
VL - 145
SP - e5
JO - American Heart Journal
JF - American Heart Journal
IS - 2
ER -