TY - JOUR
T1 - Locating hyperfunctioning parathyroid glands using 11C-Choline PET/CT
T2 - an inter- and intra-observer variation study
AU - Christensen, Julie Wulf
AU - Jensen, Lars Thorbjørn
AU - Søndergaard, Susanne Bonnichsen
AU - Broholm, Rikke
AU - Haarmark, Christian
AU - Krakauer, Martin
AU - Bennedbæk, Finn Noe
AU - Zerahn, Bo
AU - Trolle, Waldemar
AU - Hahn, Christoffer Holst
AU - Kristensen, Bent
PY - 2021/7/6
Y1 - 2021/7/6
N2 - BACKGROUND: Use of 11C-Choline PET/CT is gaining ground in detecting hyperfunctioning parathyroid glands in primary hyperparathyroidism. The purpose of this study was to evaluate the robustness of 11C-Choline PET/CT by assessing intra- and inter-observer agreement to determine whether the method was reader sensitive and therefore should only be performed at highly specialised sites with a high number of cases. PET/CT images of 40 patients diagnosed with primary hyperparathyroidism were anonymised and evaluated three times by three readers: an expert reader and two non-experts (non-experts were experienced in PET/CT imaging, but not in 11C-Choline PET/CT in the setting of primary hyperparathyroidism). Number of hyperfunctioning parathyroid glands, location relative to the thyroid gland and confidence of each assessment (low, moderate or high) were noted, and intra- and inter-observer agreement calculated using Fleiss' kappa method. Sensitivities and specificities of the non-experts were calculated using the expert reader as gold standard.RESULTS: Intra-observer agreement was 'good' to 'near perfect' for all readers. Inter-observer agreement was good between non-experts and the expert, with kappa values ≥ 0.74. Sensitivities between non-experts and the expert were high, > 81%, when assessing which side and 75% when assessing thyroid quadrant. All specificities were > 94%. Reader certainties were 'high' in > 80% of cases for the expert and > 70% and > 65%, respectively for the two non-experts.CONCLUSION: 11C-Choline PET/CT is not reader sensitive for the localisation of hyperfunctioning parathyroid glands and may therefore be safely implemented at sites that have a moderate number of cases. Access to a cyclotron laboratory is, however, a necessity for the production of 11C-Choline. The study was conducted in accordance with the Helsinki 2 declaration and The International Council for Harmonisation Guideline for Good Clinical Practice (ICH_GCP) clinical trial, approved by the Research Ethics Committee of the Capital Region of Denmark (Journal-nr.:H-18012490, date of approval: 18 June 2018) and the Danish Medicines Agency (EudraCT no. 2018-000726-63, date of approval: 6 June 2018). The GCP unit in Eastern Denmark has carried out regular monitoring of the trial according to GCP (ID: 2018-1050).
AB - BACKGROUND: Use of 11C-Choline PET/CT is gaining ground in detecting hyperfunctioning parathyroid glands in primary hyperparathyroidism. The purpose of this study was to evaluate the robustness of 11C-Choline PET/CT by assessing intra- and inter-observer agreement to determine whether the method was reader sensitive and therefore should only be performed at highly specialised sites with a high number of cases. PET/CT images of 40 patients diagnosed with primary hyperparathyroidism were anonymised and evaluated three times by three readers: an expert reader and two non-experts (non-experts were experienced in PET/CT imaging, but not in 11C-Choline PET/CT in the setting of primary hyperparathyroidism). Number of hyperfunctioning parathyroid glands, location relative to the thyroid gland and confidence of each assessment (low, moderate or high) were noted, and intra- and inter-observer agreement calculated using Fleiss' kappa method. Sensitivities and specificities of the non-experts were calculated using the expert reader as gold standard.RESULTS: Intra-observer agreement was 'good' to 'near perfect' for all readers. Inter-observer agreement was good between non-experts and the expert, with kappa values ≥ 0.74. Sensitivities between non-experts and the expert were high, > 81%, when assessing which side and 75% when assessing thyroid quadrant. All specificities were > 94%. Reader certainties were 'high' in > 80% of cases for the expert and > 70% and > 65%, respectively for the two non-experts.CONCLUSION: 11C-Choline PET/CT is not reader sensitive for the localisation of hyperfunctioning parathyroid glands and may therefore be safely implemented at sites that have a moderate number of cases. Access to a cyclotron laboratory is, however, a necessity for the production of 11C-Choline. The study was conducted in accordance with the Helsinki 2 declaration and The International Council for Harmonisation Guideline for Good Clinical Practice (ICH_GCP) clinical trial, approved by the Research Ethics Committee of the Capital Region of Denmark (Journal-nr.:H-18012490, date of approval: 18 June 2018) and the Danish Medicines Agency (EudraCT no. 2018-000726-63, date of approval: 6 June 2018). The GCP unit in Eastern Denmark has carried out regular monitoring of the trial according to GCP (ID: 2018-1050).
KW - C-Choline PET/CT
KW - Hyperparathyroidism
KW - Inter-observer agreement
KW - Intra-observer agreement
UR - http://www.scopus.com/inward/record.url?scp=85109291136&partnerID=8YFLogxK
U2 - 10.1186/s41824-021-00108-z
DO - 10.1186/s41824-021-00108-z
M3 - Journal article
C2 - 34227025
SN - 2510-3636
VL - 5
SP - 13
JO - European journal of hybrid imaging
JF - European journal of hybrid imaging
IS - 1
M1 - 13
ER -