Forskning
Udskriv Udskriv
Switch language
Region Hovedstaden - en del af Københavns Universitetshospital
Udgivet

Lobar Quantification by Ventilation/Perfusion SPECT/CT in Patients with Severe Emphysema Undergoing Lung Volume Reduction with Endobronchial Valves

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. Developing and Gathering Validity Evidence for a Simulation-Based Test of Competencies in Lung Ultrasound

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Development of and Gathering Validity Evidence for a Theoretical Test in Thoracic Ultrasound

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Endoscopic Ultrasound with Bronchoscope-Guided Fine Needle Aspiration for the Diagnosis of Paraesophageally Located Lung Lesions

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Ensuring Basic Competence in Thoracentesis

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  5. EUS-B-FNA for Diagnosing Liver and Celiac Metastases in Lung Cancer Patients

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Survival in patients with scintigraphic evidence of pulmonary thromboembolism 12 weeks after double lung transplantation

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Lung Ultrasound in the Assessment of Pulmonary Complications After Lung Transplantation

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Amyloid transthyretinkardiomyopati

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer

Background: Endoscopic lung volume reduction (ELVR) therapy using one-way valves is used to treat chronic obstructive pulmonary disease patients with severe heterogeneous emphysema. A successful treatment results in atelectasis of the treated pulmonary lobe with subsequent reduction of ventilation (V) and perfusion (Q). Objective: We evaluated the effects of ELVR on the targeted lobe using a new 3-dimensional ventilation and perfusion (V/Q) single-photon emission computed tomography (SPECT)/computed tomography (CT) analysis, which allows for simultaneous semi-automatic lobar pulmonary quantification of volume, ventilation and perfusion, on the first consecutive patients treated with ELVR at Rigshospitalet, Denmark. V/Q planar scintigraphy and V/Q SPECT/CT and lung function measurements were performed before and 6 months after intervention. Results: We included 24 subjects (60 years, range 46-74 years; 37.5% men) with a baseline FEV1 of 25% predicted and RV of 257% predicted. V/Q SPECT/CT-assessed volume of the targeted lobe decreased by a mean of -395 mL and a relative mean of -26.8%, whilst ventilation and perfusion decreased by a relative mean of -37.1 and -25.7%. There was a significant increase in the same parameters of the non-targeted lobe(s) on the ipsilateral side. None of these changes were found in the analysis of planar V/Q imaging. The total lung volume decreased on average by -420 mL. Six months after ELVR, FEV1 had increased by 22%. Significant correlations were found between changes in FEV1 and changes in the volume of the treated lobe (SPECT/CT). Conclusion: Semi-automatic SPECT/CT analysis can quantify volume, ventilation and perfusion changes in pulmonary lobes and may be used in the assessment of patient eligibility for ELVR, identifying target lobes, and evaluation of the regional effects of treatment.

OriginalsprogEngelsk
TidsskriftRespiration
Vol/bind98
Udgave nummer3
Sider (fra-til)230-238
Antal sider9
ISSN0025-7931
DOI
StatusUdgivet - 1 sep. 2019

ID: 59001352