Liquid fiducial marker performance during radiotherapy of locally advanced non small cell lung cancer

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Diffusion MRI outlined viable tumour volume beats GTV in intra-treatment stratification of outcome

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Diabetes increases the risk of serious adverse events after re-irradiation of the spine

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Influence of volumetric modulated arc therapy and FET-PET scanning on treatment outcomes for glioblastoma patients

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer
Background and purpose

We analysed the positional and structural stability of a long-term biodegradable liquid fiducial marker (BioXmark) for radiotherapy in patients with locally advanced lung cancer.

Material and methods

Markers were injected via endoscopic- or endobronchial ultrasound in lymph nodes and reachable primary tumours. Marker volume and Hounsfield Units (HU) changing rates were estimated using breath-hold CBCT. Inter-fraction variation in marker position relative to gross tumour volume (GTV) position was established, as well as the inter-fraction variation in mediastinal marker registration relative to a carina registration through the treatment.

Results

Fifteen patients were included and 29 markers analysed. All markers that were in situ at planning were visible through the treatment. Mean HU was 902 ± 165 HU for lymph node and 991 ± 219 HU for tumour markers. Volume degradation rates were −5% in lymph nodes and −23% in primary tumours. Three-dimensional inter-fraction variation for marker position relative to the GTV position was −0.1 ± 0.7 mm in lymph nodes and −1.5 ± 2.3 mm in primary tumours. Inter-fraction variations in marker registration relative to carina registration were −0.4 ± 1.2 mm in left–right, 0.2 ± 2.0 mm in anterior–posterior and −0.5 ± 2.0 mm in cranio-caudal directions.

Conclusions

The liquid fiducial markers were visible and stable in size and position throughout the treatment course.
OriginalsprogEngelsk
TidsskriftRadiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology
Vol/bind121
Udgave nummer1
Sider (fra-til)64-69
Antal sider6
ISSN0167-8140
DOI
StatusUdgivet - 18 jul. 2016