Forskning
Udskriv Udskriv
Switch language
Region Hovedstaden - en del af Københavns Universitetshospital
Udgivet

In-vivo validation of fast spectral velocity estimation techniques

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Vector velocity volume flow estimation: Sources of error and corrections applied for arteriovenous fistulas

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. First report on intraoperative vector flow imaging of the heart among patients with healthy and diseased aortic valves

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Internal strain estimation for quantification of human heel pad elastic modulus: A phantom study

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Reliable cell and tissue morphology-based diagnosis of endemic Burkitt lymphoma in resource-constrained settings in Ghana

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Elastography in Breast Imaging

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Pressure Difference Estimation in Carotid Bulbs using Vector Flow Imaging - A Phantom Study

    Publikation: Bidrag til tidsskriftKonferenceartikelForskningpeer review

Vis graf over relationer
Spectrograms in medical ultrasound are usually estimated with Welch's method (WM). WM is dependent on an observation window (OW) of up to 256 emissions per estimate to achieve sufficient spectral resolution and contrast. Two adaptive filterbank methods have been suggested to reduce the OW: Blood spectral Power Capon (BPC) and the Blood Amplitude and Phase EStimation method (BAPES). Ten volunteers were scanned over the carotid artery. From each data set, 28 spectrograms were produced by combining four approaches (WM with a Hanning window (W.HAN), WM with a boxcar window (W.BOX), BPC and BAPES) and seven OWs (128, 64, 32, 16, 8, 4, 2). The full-width-at-half-maximum (FWHM) and the ratio between main and side-lobe levels were calculated at end-diastole for each spectrogram. Furthermore, all 280 spectrograms were randomized and presented to nine radiologists for visual evaluation: useful/not useful. BAPES and BPC compared to WM had better resolution (lower FWHM) for all OW0.05) at OW 128 and 64, while W.BOX scored less (p
OriginalsprogEngelsk
TidsskriftUltrasonics
Vol/bind50
Udgave nummer1
Sider (fra-til)52-9
Antal sider8
ISSN0041-624X
DOI
StatusUdgivet - 1 jan. 2010

ID: 31044568