Forskning
Udskriv Udskriv
Switch language
Region Hovedstaden - en del af Københavns Universitetshospital
Udgivet

Intradermal Tests With Drugs: An Approach to Standardization

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. Repeated idiopathic anaphylaxis caused by povidone

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Clinical manifestations and impact on daily life of allergy to polyethylene glycol (PEG) in ten patients

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Mast cell activation test in chlorhexidine allergy: a proof of concept

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  • Annick Barbaud
  • Marie Weinborn
  • Lene Heise Garvey
  • Sergio Testi
  • Violeta Kvedariene
  • Sevim Bavbek
  • Holger Mosbech
  • Eva Gomes
  • Werner Aberer
  • Hanneke N G Oude Elberink
  • Maria Jose Torres
  • Claude Ponvert
  • C Ayav
  • Jimmy Gooi
  • Knut Brockow
Vis graf over relationer

Background: Intradermal tests (IDTs) are performed and interpreted differently in drug allergy centers making valid comparison of results difficult. Objective: To reduce method-related and intercenter variability of IDTs by the introduction of a standardized method. Materials and methods: In 11 centers of the European Network for Drug Allergy, IDTs were prospectively performed with saline and with amoxicillin (20 mg/ml) using (1) the local method and (2) the standardized European Network in Drug Allergy (ENDA) method (0.02 ml). The diameters of the initial injection wheal (Wi) for the different volumes and sites injected obtained from each center were analyzed. Results: The most reproducible method was to fill a syringe with test solution, then expel the excess fluid to obtain exactly 0.02 ml. The median Wi diameter with 0.02 ml injection using the standardized method was 5 mm [range 2-10 mm; interquartile range (IQR) 5-5 mm; n = 1,096] for saline and 5 mm (range 2-9 mm; IQR = 4.5-5 mm; n = 240) for amoxicillin. IDT injection sites did not affect the Wi diameter. Training improved precision and reduced the variability of Wi diameters. Conclusion: Using the standardized IDT method described in this multicenter study helped to reduce variability, enabling more reliable comparison of results between individuals and centers.

OriginalsprogEngelsk
TidsskriftFrontiers in Medicine
Vol/bind7
Sider (fra-til)156
ISSN2296-858X
DOI
StatusUdgivet - 15 maj 2020

Bibliografisk note

Copyright © 2020 Barbaud, Weinborn, Garvey, Testi, Kvedariene, Bavbek, Mosbech, Gomes, Aberer, Elberink, Torres, Ponvert, Ayav, Gooi and Brockow.

ID: 61764258