Forskning
Udskriv Udskriv
Switch language
Region Hovedstaden - en del af Københavns Universitetshospital
Udgivet

Intracranial entrapment of a haemodialysis catheter guidewire

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. Spontaneous intracranial hypotension presenting with progressive cognitive decline

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Severe influenza in a paediatric patient with GATA2 deficiency and Emberger syndrome

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Severe acute hepatitis E infection presenting with acute abdomen and meningoencephalitis

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Severe hypophosphataemia following oral bisphosphonate treatment in a patient with osteoporosis

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Bioimpedance as a measure of fluid status in critically ill patients: A systematic review

    Publikation: Bidrag til tidsskriftReviewForskningpeer review

  2. Cardiac arrhythmias in critically ill patients with coronavirus disease 2019: a retrospective population-based cohort study

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Nurses' Experiences and Perceptions of two Early Warning Score systems to Identify Patient Deterioration-A Focus Group Study

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. ABO blood types and sepsis mortality

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer

A 49-year-old man with chronic obstructive pulmonary disease was hospitalised due to pneumonia and pulmonary embolisms. After subsequently developing septic shock and acute renal failure, he required dialysis. A haemodialysis catheter was planned inserted into the right subclavian vein, the guidewire was introduced using the Seldinger technique. When the guidewire's 20 cm marker entered the introducer needle, it suddenly encountered resistance. Repeated attempts to remove the guidewire failed. Vital signs and haemodynamic parameters remained unchanged throughout the procedure. CT angiography revealed cranial displacement of the wire into the right internal jugular vein, with the tip of the wire just cranial to the jugular foramen in the right sigmoid sinus. Interventional radiological removal attempts were unsuccessful. Thoracic and neurosurgical interventions were considered impossible and the guidewire was left in place. Due to the pulmonary embolism and the foreign object in the patient, life-long anticoagulation was considered, with close monitoring of compliance with the patient's comorbidity and medication.

OriginalsprogEngelsk
TidsskriftBMJ Case Reports
Vol/bind13
Udgave nummer8
Sider (fra-til)e232535
ISSN1757-790X
DOI
StatusUdgivet - 25 aug. 2020

Bibliografisk note

© BMJ Publishing Group Limited 2020. No commercial re-use. See rights and permissions. Published by BMJ.