Forskning
Udskriv Udskriv
Switch language
Region Hovedstaden - en del af Københavns Universitetshospital
Udgivet

Inter-Scan Reproducibility of Carotid Plaque Volume Measurements by 3-D Ultrasound

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Contrast-Enhanced Ultrasound: Development of Syllabus for Core Theoretical and Practical Competencies

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Flow Complexity Estimation in Dysfunctional Arteriovenous Dialysis Fistulas using Vector Flow Imaging

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Commentary on the World Federation for Ultrasound in Medicine and Biology Project "Incidental Findings"

    Publikation: Bidrag til tidsskriftKommentar/debatForskningpeer review

  1. Vascular function in adults with cyanotic congenital heart disease

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Carotid atherosclerosis markers and adverse cardiovascular events

    Publikation: Bidrag til tidsskriftLetterForskningpeer review

  3. Clinical validation of three-dimensional ultrasound for abdominal aortic aneurysm

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Carotid Intima-Media Thickness Versus Carotid Plaque Burden for Predicting Cardiovascular Risk

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer

We tested a novel 3-D matrix transducer with respect to inter-scan reproducibility of carotid maximum plaque thickness (MPT) and volume measurements. To improve reproducibility while focusing on the largest plaque/most diseased part of the carotid artery, we introduced a new partial plaque volume (PPV) measure centered on MPT. Total plaque volume (TPV), PPV from a 10-mm segment and MPT were measured using dedicated semi-automated software on 38 plaques from 26 patients. Inter-scan reproducibility was assessed using the t-test, Bland-Altman plots and Pearson's correlation coefficient. There was a mean difference of 0.01 mm in MPT (limits of agreement: -0.45 to 0.42 mm, Pearson's correlation coefficient: 0.96). Both volume measurements exhibited high reproducibility, with PPV being superior (limits of agreement: -35.3 mm3to 33.5 mm3, Pearson's correlation coefficient: 0.96) to TPV (limits of agreement: -88.2 to 61.5 mm3, Pearson's correlation coefficient: 0.91). The good reproducibility revealed by the present results encourages future studies on establishing plaque quantification as part of cardiovascular risk assessment and for follow-up of disease progression over time.

OriginalsprogEngelsk
TidsskriftUltrasound in Medicine and Biology
Vol/bind44
Udgave nummer3
Sider (fra-til)670-676
Antal sider7
ISSN0301-5629
DOI
StatusUdgivet - mar. 2018

ID: 52758981