Abstract
OBJECTIVE: The influence of treatment with granulocyte-colony stimulating factor (G-CSF) on the development of in-stent intimal hyperplasia is not known. We aimed to study this phenomenon in patients who had stents implanted in the course of an acute ST-elevation infarction and successively were treated with G-CSF.
METHOD: We performed angiography and intracoronary ultrasound follow-up after 5 months in 41 consecutive patients in the STEMMI trial, which is a randomized double-blind placebo-controlled study on the effect of G-CSF injections on the myocardial function following acute myocardial infarction in patients treated with primary percutaneous coronary stent implantation. The intracoronary ultrasound images were analyzed by a blinded and independent core laboratory.
RESULTS: There were no differences in in-stent neo-intimal hyperplasia determined by intracoronary ultrasound between patients treated with G-CSF compared to patients treated with placebo. Neo-intimal hyperplasia per mm of stent was 1.87 (+/-1.41) and 1.89 (+/-1.39), respectively (p = 0.97). Angiographic in-segment restenosis (>50% diameter stenosis) was found in 28% of patients (24% in the G-CSF group and 33% in the placebo group; p = 0.55).
CONCLUSION: G-CSF treatment following coronary stent implantation in primary PCI treated AMI patients does not increase in-stent restenosis excessively and it does not seem warranted to limit further study of effects of G-CSF for that reason.
Originalsprog | Engelsk |
---|---|
Tidsskrift | International Journal of Cardiology |
Vol/bind | 111 |
Udgave nummer | 1 |
Sider (fra-til) | 174-7 |
Antal sider | 4 |
ISSN | 0167-5273 |
DOI |
|
Status | Udgivet - 28 jul. 2006 |