Forskning
Udskriv Udskriv
Switch language
Region Hovedstaden - en del af Københavns Universitetshospital
E-pub ahead of print

Improving brain B0 shimming using an easy and accessible multi-coil shim array at ultra-high field

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. Consensus-based technical recommendations for clinical translation of renal T1 and T2 mapping MRI

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Inductive measurement and encoding of k-space trajectories in MR raw data

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Survey of 800+ data sets from human tissue and body fluid reveals xenomiRs are likely artifacts

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Image artifacts from MR-based attenuation correction in clinical, whole-body PET/MRI

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Locus Coeruleus Shows a Spatial Pattern of Structural Disintegration in Parkinson's Disease

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Prospective frequency and motion correction for edited 1H magnetic resonance spectroscopy

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. 7T MRI Fractionated Dipole Antenna for Carotid Imaging

    Publikation: Bidrag til tidsskriftKonferenceartikelForskningpeer review

  4. 7T MRI Loop Antenna for Carotid Imaging

    Publikation: Bidrag til tidsskriftKonferenceartikelForskning

Vis graf over relationer

OBJECT: Improve shimming capabilities of ultra-high field systems, with addition of an accessible low-complexity B0 shim array for head MRI at 7 T.

MATERIALS AND METHODS: An eight channel B0 shim coil array was designed as a tradeoff between shimming improvement and construction complexity, to provide an easy to use shim array that can be employed with the standard 7 T head coil. The array was interfaced using an open-source eight-channel shim amplifier rack. Improvements in field homogeneity for whole-brain and slice-based shimming were compared to standard second-order shimming, and to more complex higher order dynamic shimming and shim arrays with 32 and 48 channels.

RESULTS: The eight-channel shim array provided 12% improvement in whole brain static shimming and provided 33% improvement when using slice-based shimming. With this, the eight-channel array performed similar to third-order dynamic shimming (without the need for higher order eddy current compensation). More complex shim arrays with 32 and 48 channels performed better, but require a dedicated RF coil.

DISCUSSION: The designed eight-channel shim array provides a low-complexity and low-cost approach for improving B0 field shimming on an ultra-high field system. In both static and dynamic shimming, it provides improved B0 homogeneity over standard shimming.