Forskning
Udskriv Udskriv
Switch language
Region Hovedstaden - en del af Københavns Universitetshospital
Udgivet

Identification of patients with hereditary haemochromatosis by magnetic resonance imaging and spectroscopic relaxation time measurements.

Publikation: Bidrag til tidsskriftReviewForskning

  1. Application of stereological methods to estimate post-mortem brain surface area using 3T MRI

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Coronary artery stent mimicking intracardiac thrombus on cardiac magnetic resonance imaging due to signal loss: case report

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Modelling large motion events in fMRI studies of patients with epilepsy.

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Slice profile optimization in arterial spin labeling using presaturation and optimized RF pulses

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  5. Investigation of microenvironmental factors influencing the longitudinal relaxation times of drugs and other compounds.

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  • C Thomsen
  • P Wiggers
  • H Ring-Larsen
  • E Christiansen
  • J Dalhøj
  • O Henriksen
  • P Christoffersen
Vis graf over relationer
A total of 4302 healthy blood donors were screened for elevated serum ferritin and transferrin saturation. Fifteen had increased serum ferritin at a follow-up examination. Five relatives of these donors also entered the study. Eleven patients had elevated liver iron concentrations, while five had normal liver iron concentrations. The R2 relaxation rate in the liver was first measured with a conventional multi-spin-echo imaging sequence, and then by a volume-selective spectroscopic multi-spin-echo sequence, in order to achieve a minimum echo time of 4 msec. No correlation was found between the relaxation rate R2 and the liver iron concentration, when R2 was calculated from the imaging data. Multi-exponential transverse relaxation could be resolved when the spectroscopic sequence was used. A strong correlation between the initial slope of the relaxation curve and the liver iron concentration was found (r = 0.90, p < 0.001). Signal intensity ratios between liver and muscle were calculated from the first three echoes in the multi-echo imaging sequence, and from a gradient echo sequence. A strong correlation between the logarithm of the signal intensity ratios and the liver iron concentration was found. Although both spectroscopic T2 relaxation time measurements and signal intensity ratios could be used to quantify liver iron concentration, the gradient echo imaging seemed to be the best choice. Gradient echo imaging could be performed during a single breath hold, so motion artifacts could be avoided. The accuracy of liver iron concentration estimates from signal intensity ratios in the gradient echo images was about 35%.
Bidragets oversatte titelIdentification of patients with hereditary haemochromatosis by magnetic resonance imaging and spectroscopic relaxation time measurements.
OriginalsprogEngelsk
TidsskriftMagnetic Resonance Imaging
Vol/bind10
Udgave nummer6
Sider (fra-til)867-879
Antal sider13
ISSN0730-725X
StatusUdgivet - 1992

ID: 32499596