Harvard
Jørgensen, PB
, Daugaard, H, Jakobsen, SS, Lamm, M, Søballe, K & Stilling, M 2020, '
Higher early proximal migration of hemispherical cups with electrochemically applied hydroxyapatite (BoneMaster) on a porous surface compared with porous surface alone: a randomized RSA study with 53 patients',
Acta Orthopaedica , bind 91, nr. 1, s. 26-32.
https://doi.org/10.1080/17453674.2019.1687860
APA
Jørgensen, P. B.
, Daugaard, H., Jakobsen, S. S., Lamm, M., Søballe, K., & Stilling, M. (2020).
Higher early proximal migration of hemispherical cups with electrochemically applied hydroxyapatite (BoneMaster) on a porous surface compared with porous surface alone: a randomized RSA study with 53 patients.
Acta Orthopaedica ,
91(1), 26-32.
https://doi.org/10.1080/17453674.2019.1687860
CBE
MLA
Vancouver
Author
Bibtex
@article{3fc5788a7a844aa9ba3b766c782d10b4,
title = "Higher early proximal migration of hemispherical cups with electrochemically applied hydroxyapatite (BoneMaster) on a porous surface compared with porous surface alone: a randomized RSA study with 53 patients",
abstract = "Background and purpose — BoneMaster (BM) is an electrochemically deposited hydroxyapatite (HA) implant-coating, which is evenly distributed, thin, and quickly resorbed. It is designed to stimulate osseointegration and early implant stability and alleviate longer-term HA-induced third-body polyethylene wear. This study evaluates early cup migration and functional outcomes of cementless porous-coated hemispherical cups with or without BM. Patients and methods — In a patient-blinded, randomized, controlled trial 53 patients at mean 64 years (55–75) with coxarthritis were operated with an Exceed cup (Zimmer Biomet) and Bi-Metric stem (Zimmer Biomet) with porous and BM coating (PBM) or with porous coating alone (P). Follow-ups were performed postoperatively and at 3, 6, 12, and 24 months. Effect measures were cup migration measured with RSA and PROMs. Results — At 6-month follow-up, proximal cup migration in the PBM group (0.09 mm, 95% CI 0.02–0.20) was higher than in the P group (0.25 mm, CI 0.15–0.35). At 1- and 2-year follow-up, cup migration in all 6 degrees of freedom was similar between groups (p > 0.2). From before surgery to 2-year follow-up, Oxford Hip Score (OHS) increased by 17 points (CI 14–20). Hip disability and Osteoarthritis Outcome Score (HOOS) increased in all sub-scores, but was more pronounced for PBM cups compared with P cups in the Symptoms sub-score (p = 0.04). Interpretation — Contrary to expectations, PBM cups had higher early migration than P cups. At 2-year follow-up, migration was similar between groups. There seems to be no early benefit of BM coating on acetabular cups.",
author = "J{\o}rgensen, {Peter Bo} and Henrik Daugaard and Jakobsen, {Stig Storgaard} and Martin Lamm and Kjeld S{\o}balle and Maiken Stilling",
note = "Publisher Copyright: {\textcopyright} 2019, {\textcopyright} 2019 The Author(s). Published by Taylor & Francis on behalf of the Nordic Orthopedic Federation. Copyright: Copyright 2020 Elsevier B.V., All rights reserved.",
year = "2020",
month = jan,
day = "2",
doi = "10.1080/17453674.2019.1687860",
language = "English",
volume = "91",
pages = "26--32",
journal = "Acta Orthopaedica ",
issn = "1745-3674",
publisher = "Taylor & Francis Ltd",
number = "1",
}
RIS
TY - JOUR
T1 - Higher early proximal migration of hemispherical cups with electrochemically applied hydroxyapatite (BoneMaster) on a porous surface compared with porous surface alone
T2 - a randomized RSA study with 53 patients
AU - Jørgensen, Peter Bo
AU - Daugaard, Henrik
AU - Jakobsen, Stig Storgaard
AU - Lamm, Martin
AU - Søballe, Kjeld
AU - Stilling, Maiken
N1 - Publisher Copyright:
© 2019, © 2019 The Author(s). Published by Taylor & Francis on behalf of the Nordic Orthopedic Federation.
Copyright:
Copyright 2020 Elsevier B.V., All rights reserved.
PY - 2020/1/2
Y1 - 2020/1/2
N2 - Background and purpose — BoneMaster (BM) is an electrochemically deposited hydroxyapatite (HA) implant-coating, which is evenly distributed, thin, and quickly resorbed. It is designed to stimulate osseointegration and early implant stability and alleviate longer-term HA-induced third-body polyethylene wear. This study evaluates early cup migration and functional outcomes of cementless porous-coated hemispherical cups with or without BM. Patients and methods — In a patient-blinded, randomized, controlled trial 53 patients at mean 64 years (55–75) with coxarthritis were operated with an Exceed cup (Zimmer Biomet) and Bi-Metric stem (Zimmer Biomet) with porous and BM coating (PBM) or with porous coating alone (P). Follow-ups were performed postoperatively and at 3, 6, 12, and 24 months. Effect measures were cup migration measured with RSA and PROMs. Results — At 6-month follow-up, proximal cup migration in the PBM group (0.09 mm, 95% CI 0.02–0.20) was higher than in the P group (0.25 mm, CI 0.15–0.35). At 1- and 2-year follow-up, cup migration in all 6 degrees of freedom was similar between groups (p > 0.2). From before surgery to 2-year follow-up, Oxford Hip Score (OHS) increased by 17 points (CI 14–20). Hip disability and Osteoarthritis Outcome Score (HOOS) increased in all sub-scores, but was more pronounced for PBM cups compared with P cups in the Symptoms sub-score (p = 0.04). Interpretation — Contrary to expectations, PBM cups had higher early migration than P cups. At 2-year follow-up, migration was similar between groups. There seems to be no early benefit of BM coating on acetabular cups.
AB - Background and purpose — BoneMaster (BM) is an electrochemically deposited hydroxyapatite (HA) implant-coating, which is evenly distributed, thin, and quickly resorbed. It is designed to stimulate osseointegration and early implant stability and alleviate longer-term HA-induced third-body polyethylene wear. This study evaluates early cup migration and functional outcomes of cementless porous-coated hemispherical cups with or without BM. Patients and methods — In a patient-blinded, randomized, controlled trial 53 patients at mean 64 years (55–75) with coxarthritis were operated with an Exceed cup (Zimmer Biomet) and Bi-Metric stem (Zimmer Biomet) with porous and BM coating (PBM) or with porous coating alone (P). Follow-ups were performed postoperatively and at 3, 6, 12, and 24 months. Effect measures were cup migration measured with RSA and PROMs. Results — At 6-month follow-up, proximal cup migration in the PBM group (0.09 mm, 95% CI 0.02–0.20) was higher than in the P group (0.25 mm, CI 0.15–0.35). At 1- and 2-year follow-up, cup migration in all 6 degrees of freedom was similar between groups (p > 0.2). From before surgery to 2-year follow-up, Oxford Hip Score (OHS) increased by 17 points (CI 14–20). Hip disability and Osteoarthritis Outcome Score (HOOS) increased in all sub-scores, but was more pronounced for PBM cups compared with P cups in the Symptoms sub-score (p = 0.04). Interpretation — Contrary to expectations, PBM cups had higher early migration than P cups. At 2-year follow-up, migration was similar between groups. There seems to be no early benefit of BM coating on acetabular cups.
UR - http://www.scopus.com/inward/record.url?scp=85074969373&partnerID=8YFLogxK
U2 - 10.1080/17453674.2019.1687860
DO - 10.1080/17453674.2019.1687860
M3 - Journal article
C2 - 31698977
AN - SCOPUS:85074969373
VL - 91
SP - 26
EP - 32
JO - Acta Orthopaedica
JF - Acta Orthopaedica
SN - 1745-3674
IS - 1
ER -