TY - JOUR
T1 - Heart rate responses, agreement and accuracy among persons with severe disabilities participating in the indirect movement program
T2 - Team Twin-an observational study
AU - Jørgensen, Andreas
AU - Toftager, Mette
AU - Eghøj, Martin
AU - Ried-Larsen, Mathias
AU - Bjørk Petersen, Christina
N1 - © 2023 Jørgensen, Toftager, Eghøj, Ried-Larsen and Bjørk Petersen.
PY - 2023
Y1 - 2023
N2 - INTRODUCTION: Heart rate (HR) monitors are rarely used by people living with disabilities (PLWD), and their accuracy is undocumented. Thus, this study aims to describe the HR response during the Team Twin co-running program and, secondly, to assess the agreement and accuracy of using HR monitors among PLWD.METHODS: This 16-week single-arm observational study included 18 people with various disabilities. During the study, the subjects wore a Garmin Vivosmart 4 watch (wrist). To evaluate the agreement and accuracy we applied Garmin's HRM-DUAL™ chest-worn HR monitors for comparison with the Vivosmart 4. The HR response analysis was performed descriptively and with a mixed regression model. The HR agreement and accuracy procedure was conducted on a subsample of five subjects and analyzed using Lin's concordance analysis, Bland and Altman's limits of agreement, and Cohen's kappa analysis of intensity zone agreement. This study was prospectively registered at Clinical Trials.gov (NCT04536779).RESULTS: The subjects had a mean age of 35 (±12.6), 61% were male, 72% had cerebral palsy were 85% had GMFCS V-IV. HR was monitored for 202:10:33 (HH:MM:SS), with a mean HR of 90 ± 17 bpm during training and race. A total of 19% of the time was spent in intensity zones between light and moderate (30%-59% HR reserve) and 1% in vigorous (60%-84% HR reserve). The remaining 80% were in the very light intensity zone (<29% HR reserve). HR was highest at the start of race and training and steadily decreased. Inter-rater agreement was high (k = 0.75), limits of agreement were between -16 and 13 bpm, and accuracy was acceptable (Rc = 0.86).CONCLUSION: Disability type, individual, and contextual factors will likely affect HR responses and the agreement and accuracy for PLWD. The Vivosmart 4, while overall accurate, had low precision due to high variability in the estimation. These findings implicate the methodical and practical difficulties of utilizing HR monitors to measure HR and thus physical activity in adapted sports activities for severely disabled individuals.
AB - INTRODUCTION: Heart rate (HR) monitors are rarely used by people living with disabilities (PLWD), and their accuracy is undocumented. Thus, this study aims to describe the HR response during the Team Twin co-running program and, secondly, to assess the agreement and accuracy of using HR monitors among PLWD.METHODS: This 16-week single-arm observational study included 18 people with various disabilities. During the study, the subjects wore a Garmin Vivosmart 4 watch (wrist). To evaluate the agreement and accuracy we applied Garmin's HRM-DUAL™ chest-worn HR monitors for comparison with the Vivosmart 4. The HR response analysis was performed descriptively and with a mixed regression model. The HR agreement and accuracy procedure was conducted on a subsample of five subjects and analyzed using Lin's concordance analysis, Bland and Altman's limits of agreement, and Cohen's kappa analysis of intensity zone agreement. This study was prospectively registered at Clinical Trials.gov (NCT04536779).RESULTS: The subjects had a mean age of 35 (±12.6), 61% were male, 72% had cerebral palsy were 85% had GMFCS V-IV. HR was monitored for 202:10:33 (HH:MM:SS), with a mean HR of 90 ± 17 bpm during training and race. A total of 19% of the time was spent in intensity zones between light and moderate (30%-59% HR reserve) and 1% in vigorous (60%-84% HR reserve). The remaining 80% were in the very light intensity zone (<29% HR reserve). HR was highest at the start of race and training and steadily decreased. Inter-rater agreement was high (k = 0.75), limits of agreement were between -16 and 13 bpm, and accuracy was acceptable (Rc = 0.86).CONCLUSION: Disability type, individual, and contextual factors will likely affect HR responses and the agreement and accuracy for PLWD. The Vivosmart 4, while overall accurate, had low precision due to high variability in the estimation. These findings implicate the methodical and practical difficulties of utilizing HR monitors to measure HR and thus physical activity in adapted sports activities for severely disabled individuals.
UR - http://www.scopus.com/inward/record.url?scp=85175861442&partnerID=8YFLogxK
U2 - 10.3389/fspor.2023.1213655
DO - 10.3389/fspor.2023.1213655
M3 - Journal article
C2 - 37941848
SN - 2624-9367
VL - 5
JO - Frontiers in sports and active living
JF - Frontiers in sports and active living
M1 - 1213655
ER -