T1 - Fundus imaging and perimetry in patients with idiopathic intracranial hypertension - an intermethod and interrater validity study
AU - Rissan, Zainab
AU - Hansen, Nadja Skadkaer
AU - Carlsen, Louise Ninett
AU - Korsbaek, Johanne Juhl
AU - Jensen, Rigmor Højland
AU - Hamann, Steffen
AU - Winther Schytz, Henrik
N1 - This article is protected by copyright. All rights reserved.
PY - 2023/3/27
Y1 - 2023/3/27
N2 - BACKGROUND AND PURPOSE: There is a need to improve the diagnostic process of patients suspected of papilledema. In patients with known or suspected idiopathic intracranial hypertension a fundus imaging and perimetric visual field assessment system (COMPASS) performed at a headache center was validated in comparison to an assessment (Topcon plus OCTOPUS) at a neuroophthalmological clinic.METHODS: For intermethod assessment, blinded fundus images and perimetry from COMPASS versus Topcon plus OCTOPUS were assessed by a neuroophthalmologist. For interrater assessment, fundus images and perimetry obtained by the COMPASS system were assessed by an untrained medical doctor, a trained neurologist and a trained medical student and compared to the neuroophthalmologist's assessments.RESULTS: For the intermethod variation of the presence of papilledema on fundus images, a kappa value of 0.60, sensitivity of 87% and specificity of 73% were found. The interrater variation of the presence of papilledema on fundus images showed kappa values ranging from 0.43 to 0.74, sensitivity values ranging from 70% to 96% and specificity values ranging from 46% to 93% when comparing the assessments made by the headache center staff with neuroophthalmologist's assessments. The COMPASS showed a 59% sensitivity and moderate agreement in detecting visual field defects compared with OCTOPUS. The visual field assessment showed only slight to fair agreement from 0.19 to 0.31 between assessments made by the headache center staff and the neuroophthalmologist.CONCLUSION: The COMPASS system can be used with reasonable sensitivity in the assessment of papilledema in patients suspected of idiopathic intracranial hypertension at a tertiary headache center.
AB - BACKGROUND AND PURPOSE: There is a need to improve the diagnostic process of patients suspected of papilledema. In patients with known or suspected idiopathic intracranial hypertension a fundus imaging and perimetric visual field assessment system (COMPASS) performed at a headache center was validated in comparison to an assessment (Topcon plus OCTOPUS) at a neuroophthalmological clinic.METHODS: For intermethod assessment, blinded fundus images and perimetry from COMPASS versus Topcon plus OCTOPUS were assessed by a neuroophthalmologist. For interrater assessment, fundus images and perimetry obtained by the COMPASS system were assessed by an untrained medical doctor, a trained neurologist and a trained medical student and compared to the neuroophthalmologist's assessments.RESULTS: For the intermethod variation of the presence of papilledema on fundus images, a kappa value of 0.60, sensitivity of 87% and specificity of 73% were found. The interrater variation of the presence of papilledema on fundus images showed kappa values ranging from 0.43 to 0.74, sensitivity values ranging from 70% to 96% and specificity values ranging from 46% to 93% when comparing the assessments made by the headache center staff with neuroophthalmologist's assessments. The COMPASS showed a 59% sensitivity and moderate agreement in detecting visual field defects compared with OCTOPUS. The visual field assessment showed only slight to fair agreement from 0.19 to 0.31 between assessments made by the headache center staff and the neuroophthalmologist.CONCLUSION: The COMPASS system can be used with reasonable sensitivity in the assessment of papilledema in patients suspected of idiopathic intracranial hypertension at a tertiary headache center.
UR - http://www.scopus.com/inward/record.url?scp=85152297138&partnerID=8YFLogxK
U2 - 10.1111/ene.15802
DO - 10.1111/ene.15802
M3 - Journal article
C2 - 36971767
JO - European Journal of Neurology
JF - European Journal of Neurology
SN - 1351-5101
ER -