Fluispotter, a novel automated and wearable device for accurate volume serial dried blood spot sampling

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. Simultaneous quantification of high-dose naloxone and naloxone-3-β-d-glucuronide in human plasma by UHPLC-MS/MS

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. The influence of sample collection methodology and sample preprocessing on the blood metabolic profile

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Development of a fast method for direct analysis of intact synthetic insulins in human plasma: the large peptide challenge

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Current strategies in the discovery of small-molecule biomarkers for Alzheimer's disease

    Publikation: Bidrag til tidsskriftReviewForskningpeer review

  1. Hashimoto's thyroiditis as a risk factor for thyroid cancer

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Disease Control and Gender Predict the Socioeconomic Effects of Acromegaly: A Nationwide Cohort Study

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Ecological momentary assessments (EMAs) did not improve responsiveness of patient-reported outcomes on quality of life

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Is the alpha-galactosidase A variant p.Asp313Tyr (p.D313Y) pathogenic for Fabry disease? A systematic review

    Publikation: Bidrag til tidsskriftReviewForskningpeer review

Vis graf over relationer

Aim: A novel automated serial dried blood spot (DBS) sampler, 'Fluispotter', was tested for its sampling performance. Materials & methods: An LC-MS/MS method was developed for the analysis of cortisol in DBS samples serially spotted by Fluispotter. The cortisol concentrations in 148 paired DBS and plasma samples were compared across a hematocrit (HCT) range of 22-55%. Results: The interassay accuracy and precision were <10%. Overall assay bias was negligible across the HCTs tested when analyzing the whole-spot DBS samples. The accuracy and precision of the blood volume in 10 μl DBS samples spotted by Fluispotters and micropipettes were within 3%. Deming regression and Bland-Altman analysis showed a good agreement of DBS-predicted and measured plasma cortisol. Conclusion: The Fluispotter performed serial sampling with high accuracy and precision of the sample blood volume.

OriginalsprogEngelsk
TidsskriftBioanalysis
Vol/bind12
Udgave nummer10
Sider (fra-til)665-681
Antal sider17
ISSN1757-6180
DOI
StatusUdgivet - 2020