Forskning
Udskriv Udskriv
Switch language
Region Hovedstaden - en del af Københavns Universitetshospital
Udgivet

Feasibility of Telemetric Intracranial Pressure Monitoring in the Neuro Intensive Care Unit

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Harvard

APA

CBE

MLA

Vancouver

Author

Bibtex

@article{b3c935aec35948ef881e9a8ce71a8b18,
title = "Feasibility of Telemetric Intracranial Pressure Monitoring in the Neuro Intensive Care Unit",
abstract = "Intracranial pressure (ICP) monitoring is crucial in the management of acute neurosurgical conditions such as traumatic brain injury (TBI). However, pathological ICP may persist beyond the admission to the neuro intensive care unit (NICU). We investigated the feasibility of telemetric ICP monitoring in the NICU, as this technology provides the possibility of long-term ICP assessment beyond NICU discharge. In this prospective investigation, we implanted telemetric ICP sensors (Raumedic Neurovent-P-tel) instead of conventional, cabled ICP sensors in patients undergoing decompressive craniectomy. We recorded ICP curves, duration of ICP monitoring, signal quality, and complications. Seventeen patients were included (median age 55 years) and diagnoses were: severe TBI (8), malignant middle cerebral artery infarction (8), and spontaneous intracerebral hemorrhage (1). In total, 3015 h of ICP monitoring were performed, and the median duration of ICP monitoring was 188 h (interquartile range [IQR] 54-259). The ICP signal was lost 613 times (displacement of the reader unit on the skin) for a median of 1.5 min, corresponding to 0.8{\%} of the total monitoring period. When the signal was lost, it could always be restored by realignment of the reader unit on the skin above the telemetric sensor. Sixteen of 17 patients survived the NICU admission, and ICP gradually decreased from 10.7 mm Hg (IQR 7.5-13.6) during the first postoperative day to 6.3 mm Hg (IQR 4.0-8.3) after 1 week in the NICU. All 17 implanted telemetric sensors functioned throughout the NICU admission, and no wound infections were observed. Therefore, telemetric ICP monitoring in an acute neurosurgical setting is feasible. Signal quality and stability are sufficient for clinical decision making based on mean ICP. The low sampling frequency (5 Hz) does not permit analysis of intracranial pulse wave morphology, but resolution is sufficient for calculation of derived indices such as the pressure reactivity index (PRx).",
author = "Alexander Lilja-Cyron and Jesper Kelsen and Morten Andresen and K{\aa}re Fugleholm and Marianne Juhler",
year = "2018",
month = "7",
day = "15",
doi = "10.1089/neu.2017.5589",
language = "English",
volume = "35",
pages = "1578--1586",
journal = "Journal of Neurotrauma",
issn = "0897-7151",
publisher = "Mary Ann Liebert Inc.",
number = "14",

}

RIS

TY - JOUR

T1 - Feasibility of Telemetric Intracranial Pressure Monitoring in the Neuro Intensive Care Unit

AU - Lilja-Cyron, Alexander

AU - Kelsen, Jesper

AU - Andresen, Morten

AU - Fugleholm, Kåre

AU - Juhler, Marianne

PY - 2018/7/15

Y1 - 2018/7/15

N2 - Intracranial pressure (ICP) monitoring is crucial in the management of acute neurosurgical conditions such as traumatic brain injury (TBI). However, pathological ICP may persist beyond the admission to the neuro intensive care unit (NICU). We investigated the feasibility of telemetric ICP monitoring in the NICU, as this technology provides the possibility of long-term ICP assessment beyond NICU discharge. In this prospective investigation, we implanted telemetric ICP sensors (Raumedic Neurovent-P-tel) instead of conventional, cabled ICP sensors in patients undergoing decompressive craniectomy. We recorded ICP curves, duration of ICP monitoring, signal quality, and complications. Seventeen patients were included (median age 55 years) and diagnoses were: severe TBI (8), malignant middle cerebral artery infarction (8), and spontaneous intracerebral hemorrhage (1). In total, 3015 h of ICP monitoring were performed, and the median duration of ICP monitoring was 188 h (interquartile range [IQR] 54-259). The ICP signal was lost 613 times (displacement of the reader unit on the skin) for a median of 1.5 min, corresponding to 0.8% of the total monitoring period. When the signal was lost, it could always be restored by realignment of the reader unit on the skin above the telemetric sensor. Sixteen of 17 patients survived the NICU admission, and ICP gradually decreased from 10.7 mm Hg (IQR 7.5-13.6) during the first postoperative day to 6.3 mm Hg (IQR 4.0-8.3) after 1 week in the NICU. All 17 implanted telemetric sensors functioned throughout the NICU admission, and no wound infections were observed. Therefore, telemetric ICP monitoring in an acute neurosurgical setting is feasible. Signal quality and stability are sufficient for clinical decision making based on mean ICP. The low sampling frequency (5 Hz) does not permit analysis of intracranial pulse wave morphology, but resolution is sufficient for calculation of derived indices such as the pressure reactivity index (PRx).

AB - Intracranial pressure (ICP) monitoring is crucial in the management of acute neurosurgical conditions such as traumatic brain injury (TBI). However, pathological ICP may persist beyond the admission to the neuro intensive care unit (NICU). We investigated the feasibility of telemetric ICP monitoring in the NICU, as this technology provides the possibility of long-term ICP assessment beyond NICU discharge. In this prospective investigation, we implanted telemetric ICP sensors (Raumedic Neurovent-P-tel) instead of conventional, cabled ICP sensors in patients undergoing decompressive craniectomy. We recorded ICP curves, duration of ICP monitoring, signal quality, and complications. Seventeen patients were included (median age 55 years) and diagnoses were: severe TBI (8), malignant middle cerebral artery infarction (8), and spontaneous intracerebral hemorrhage (1). In total, 3015 h of ICP monitoring were performed, and the median duration of ICP monitoring was 188 h (interquartile range [IQR] 54-259). The ICP signal was lost 613 times (displacement of the reader unit on the skin) for a median of 1.5 min, corresponding to 0.8% of the total monitoring period. When the signal was lost, it could always be restored by realignment of the reader unit on the skin above the telemetric sensor. Sixteen of 17 patients survived the NICU admission, and ICP gradually decreased from 10.7 mm Hg (IQR 7.5-13.6) during the first postoperative day to 6.3 mm Hg (IQR 4.0-8.3) after 1 week in the NICU. All 17 implanted telemetric sensors functioned throughout the NICU admission, and no wound infections were observed. Therefore, telemetric ICP monitoring in an acute neurosurgical setting is feasible. Signal quality and stability are sufficient for clinical decision making based on mean ICP. The low sampling frequency (5 Hz) does not permit analysis of intracranial pulse wave morphology, but resolution is sufficient for calculation of derived indices such as the pressure reactivity index (PRx).

U2 - 10.1089/neu.2017.5589

DO - 10.1089/neu.2017.5589

M3 - Journal article

VL - 35

SP - 1578

EP - 1586

JO - Journal of Neurotrauma

JF - Journal of Neurotrauma

SN - 0897-7151

IS - 14

ER -