Forskning
Udskriv Udskriv
Switch language
Region Hovedstaden - en del af Københavns Universitetshospital
Udgivet

Fast Selective Detection of Pyocyanin Using Cyclic Voltammetry

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. Estimating Throwing Speed in Handball Using a Wearable Device

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Evaluation of Commercial Self-Monitoring Devices for Clinical Purposes: Results from the Future Patient Trial, Phase I

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Primary ciliary dyskinesia patients have the same P. aeruginosa clone in sinuses and lungs

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Structure of Pseudomonas aeruginosa ribosomes from an aminoglycoside-resistant clinical isolate

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Filamentous bacteriophages are associated with chronic Pseudomonas lung infections and antibiotic resistance in cystic fibrosis

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer

Pyocyanin is a virulence factor uniquely produced by the pathogen Pseudomonas aeruginosa. The fast and selective detection of pyocyanin in clinical samples can reveal important information about the presence of this microorganism in patients. Electrochemical sensing of the redox-active pyocyanin is a route to directly quantify pyocyanin in real time and in situ in hospitals and clinics. The selective quantification of pyocyanin is, however, limited by other redox-active compounds existing in human fluids and by other metabolites produced by pathogenic bacteria. Here we present a direct selective method to detect pyocyanin in a complex electroactive environment using commercially available electrodes. It is shown that cyclic voltammetry measurements between -1.0 V to 1.0 V reveal a potential detection window of pyocyanin of 0.58-0.82 V that is unaffected by other redox-active interferents. The linear quantification of pyocyanin has an R² value of 0.991 across the clinically relevant concentration range of 2-100 µM. The proposed method was tested on human saliva showing a standard deviation of 2.5% ± 1% (n = 5) from the known added pyocyanin concentration to the samples. This inexpensive procedure is suggested for clinical use in monitoring the presence and state of P. aeruginosa infection in patients.

OriginalsprogEngelsk
TidsskriftSensors
Vol/bind16
Udgave nummer3
Sider (fra-til)E408
ISSN1424-3210
DOI
StatusUdgivet - 19 mar. 2016

ID: 49928484