Fast and sensitive high performance liquid chromatography analysis of cosmetic creams for hydroquinone, phenol and six preservatives

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Discovery and validation of plasma proteomic biomarkers relating to brain amyloid burden by SOMAscan assay

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Neurotransmitter Imbalance in the Brain and Alzheimer’s Disease Pathology

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Impact of binge drinking on hepatic lipid metabolism: lipidome analysis of liver vein and peripheral blood during acute alcohol intoxication

    Publikation: Bidrag til tidsskriftKonferenceabstrakt i tidsskriftForskningpeer review

  4. Polyols and Branched Chained Amino Acids Are Associated with Present and Future Renal Impairment in Type 1 Diabetes

    Publikation: Bidrag til tidsskriftKonferenceabstrakt i tidsskriftForskningpeer review

Vis graf over relationer

A fast and sensitive HPLC method for analysis of cosmetic creams for hydroquinone, phenol and six preservatives has been developed. The influence of sample preparation conditions and the composition of the mobile phase and elution mode were investigated to optimize the separation of the eight studied components. Final conditions were 60% methanol and 40% water (v/v) extraction of the cosmetic creams. A C18 column (100 mm × 2.1 mm) was used as the separation column and the mobile phase consisted of methanol and 0.05 mol/L ammonium formate in water (pH=3.0) with gradient elution. The results showed that complete separation of the eight studied components was achieved within 10 min, the linear ranges were 1.0-200 μg/mL for phenol, 0.1-150 μg/mL for sorbic acid, 2.0-200 μg/mL for benzoic acid, 0.5-200 μg/mL for hydroquinone, methyl paraben, ethyl paraben and propyl paraben, butyl paraben, and good linear correlation coefficient (≥0.9997) were obtained, the detection limit was in the range of 0.05-1.0 μg/mL, the average recovery was between 86.5% and 116.3%, and the relative standard deviation (RSD) was less than 5.0% (n=6). The method is easy, fast and sensitive, it can be employed to analyze component residues in cosmetic creams especially in a quality control setting.

OriginalsprogEngelsk
TidsskriftJournal of Chromatography
Vol/bind1218
Udgave nummer28
Sider (fra-til)4307-11
Antal sider5
ISSN0021-9673
DOI
StatusUdgivet - 15 jul. 2011
Eksternt udgivetJa

ID: 54961455