T1 - Evaluation of analytical accuracy of HER2 status in patients with breast cancer
T2 - Comparison of HER2 GPA with HER2 IHC and HER2 FISH
AU - Jensen, Steffen Grann
AU - Thomas, Peter Engel
AU - Christensen, Ib Jarle
AU - Balslev, Eva
AU - Hansen, Alastair
AU - Høgdall, Estrid
N1 - © 2020 Scandinavian Societies for Medical Microbiology and Pathology.
PY - 2020/11
Y1 - 2020/11
N2 - Human epidermal growth factor receptor 2 (HER2) gene status and overexpression, occurring in ~ 13.6% of primary breast cancers, is essential for identifying patients likely to benefit from biological treatment. In this method of evaluation study, we tested and compared the HER2 gene-protein assay (GPA) with routine HER2 immunohistochemistry (IHC) and fluorescence in situ hybridization (FISH). The GPA was evaluated using 67 formalin-fixed paraffin-embedded (FFPE) HER2 equivoval IHC (2+) breast cancer tissue samples. Overall, agreement between GPA silver in situ hybridization (SISH) and FISH was 91.9% (57/62). Regression analysis revealed slightly higher, but non-significant difference in HER2/chromosome enumeration probe 17 (CEP17) ratio for GPA as compared to FISH (p = 0.074). Intraclass correlation coefficients (ICCs) of 0.94 and Spearman´s rank correlation coefficients of 0.93 (p < 0.0001) for FISH and GPA SISH suggested strong inter-observer association for methods with one observer counting on average 0.23 significant higher for GPA SISH (p = 0.014). Intra-observer IHC method reproducibility was 52.6% (κ = 0.3122, p = 0.004) and 79.7% (κ = 0.6428, p = 0.9197), suggesting fair significant and substantial non-significant difference between tests for reviewers. Inter-observer reproducibility for IHC methods was 53%. While inter-observer reproducibility for experienced IHC interpretation suggested significant differences (κ = 0.3636, p = 0.0332), unexperienced interpretation of IHC GPA suggested fair non-significant difference between reviewers (κ = 0.3101, p = 0.0747). Using FISH as reference, the diagnostic indices for GPA SISH were as follows: sensitivity 100%, specificity 95% and accuracy 92%. Inaccuracy between tests was in 80% of cases due to ISH categorization as equivocal by one of the methods. IHC results highlight that it may be beneficial with a method for simultaneously visualization of HER2 gene and protein status.
AB - Human epidermal growth factor receptor 2 (HER2) gene status and overexpression, occurring in ~ 13.6% of primary breast cancers, is essential for identifying patients likely to benefit from biological treatment. In this method of evaluation study, we tested and compared the HER2 gene-protein assay (GPA) with routine HER2 immunohistochemistry (IHC) and fluorescence in situ hybridization (FISH). The GPA was evaluated using 67 formalin-fixed paraffin-embedded (FFPE) HER2 equivoval IHC (2+) breast cancer tissue samples. Overall, agreement between GPA silver in situ hybridization (SISH) and FISH was 91.9% (57/62). Regression analysis revealed slightly higher, but non-significant difference in HER2/chromosome enumeration probe 17 (CEP17) ratio for GPA as compared to FISH (p = 0.074). Intraclass correlation coefficients (ICCs) of 0.94 and Spearman´s rank correlation coefficients of 0.93 (p < 0.0001) for FISH and GPA SISH suggested strong inter-observer association for methods with one observer counting on average 0.23 significant higher for GPA SISH (p = 0.014). Intra-observer IHC method reproducibility was 52.6% (κ = 0.3122, p = 0.004) and 79.7% (κ = 0.6428, p = 0.9197), suggesting fair significant and substantial non-significant difference between tests for reviewers. Inter-observer reproducibility for IHC methods was 53%. While inter-observer reproducibility for experienced IHC interpretation suggested significant differences (κ = 0.3636, p = 0.0332), unexperienced interpretation of IHC GPA suggested fair non-significant difference between reviewers (κ = 0.3101, p = 0.0747). Using FISH as reference, the diagnostic indices for GPA SISH were as follows: sensitivity 100%, specificity 95% and accuracy 92%. Inaccuracy between tests was in 80% of cases due to ISH categorization as equivocal by one of the methods. IHC results highlight that it may be beneficial with a method for simultaneously visualization of HER2 gene and protein status.
KW - Biomarkers, Tumor/genetics
KW - Breast Neoplasms/diagnosis
KW - Carcinoma/diagnosis
KW - Female
KW - Gene Expression
KW - Humans
KW - Immunohistochemistry
KW - In Situ Hybridization, Fluorescence
KW - Lymphatic Metastasis
KW - Observer Variation
KW - Protein Array Analysis
KW - Receptor, ErbB-2/genetics
KW - Reproducibility of Results
KW - Sensitivity and Specificity