T1 - EUropean real-world outcomes with Pulsed field ablatiOn in patients with symptomatic atRIAl fibrillation
T2 - lessons from the multi-centre EU-PORIA registry
AU - Schmidt, Boris
AU - Bordignon, Stefano
AU - Neven, Kars
AU - Reichlin, Tobias
AU - Blaauw, Yuri
AU - Hansen, Jim
AU - Adelino, Raquel
AU - Ouss, Alexandre
AU - Füting, Anna
AU - Roten, Laurent
AU - Mulder, Bart A
AU - Ruwald, Martin H
AU - Mené, Roberto
AU - van der Voort, Pepijn
AU - Reinsch, Nico
AU - Kueffer, Thomas
AU - Boveda, Serge
AU - Albrecht, Elizabeth M
AU - Schneider, Christopher W
AU - Chun, Kyoung Ryul Julian
N1 - © The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology.
PY - 2023/7/4
Y1 - 2023/7/4
N2 - AIMS: Pulsed field ablation (PFA) is a new, non-thermal ablation modality for pulmonary vein (PV) isolation in patients with atrial fibrillation (AF). The multi-centre EUropean Real World Outcomes with Pulsed Field AblatiOn in Patients with Symptomatic AtRIAl Fibrillation (EU-PORIA) registry sought to determine the safety, efficacy, and learning curve characteristics for the pentaspline, multi-electrode PFA catheter.METHODS AND RESULTS: All-comer AF patients from seven high-volume centres were consecutively enrolled. Procedural and follow-up data were collected. Learning curve effects were analysed by operator ablation experience and primary ablation modality. In total, 1233 patients (61% male, mean age 66 ± 11years, 60% paroxysmal AF) were treated by 42 operators. In 169 patients (14%), additional lesions outside the PVs were performed, most commonly at the posterior wall (n = 127). Median procedure and fluoroscopy times were 58 (interquartile range: 40-87) and 14 (9-21) min, respectively, with no differences due to operator experience. Major complications occurred in 21/1233 procedures (1.7%) including pericardial tamponade (14; 1.1%) and transient ischaemic attack or stroke (n = 7; 0.6%), of which one was fatal. Prior cryoballoon users had less complication. At a median follow-up of 365 (323-386) days, the Kaplan-Meier estimate of arrhythmia-free survival was 74% (80% for paroxysmal and 66% for persistent AF). Freedom from arrhythmia was not influenced by operator experience. In 149 (12%) patients, a repeat procedure was performed due to AF recurrence and 418/584 (72%) PVs were durably isolated.CONCLUSION: The EU-PORIA registry demonstrates a high single-procedure success rate with an excellent safety profile and short procedure times in a real-world, all-comer AF patient population.
AB - AIMS: Pulsed field ablation (PFA) is a new, non-thermal ablation modality for pulmonary vein (PV) isolation in patients with atrial fibrillation (AF). The multi-centre EUropean Real World Outcomes with Pulsed Field AblatiOn in Patients with Symptomatic AtRIAl Fibrillation (EU-PORIA) registry sought to determine the safety, efficacy, and learning curve characteristics for the pentaspline, multi-electrode PFA catheter.METHODS AND RESULTS: All-comer AF patients from seven high-volume centres were consecutively enrolled. Procedural and follow-up data were collected. Learning curve effects were analysed by operator ablation experience and primary ablation modality. In total, 1233 patients (61% male, mean age 66 ± 11years, 60% paroxysmal AF) were treated by 42 operators. In 169 patients (14%), additional lesions outside the PVs were performed, most commonly at the posterior wall (n = 127). Median procedure and fluoroscopy times were 58 (interquartile range: 40-87) and 14 (9-21) min, respectively, with no differences due to operator experience. Major complications occurred in 21/1233 procedures (1.7%) including pericardial tamponade (14; 1.1%) and transient ischaemic attack or stroke (n = 7; 0.6%), of which one was fatal. Prior cryoballoon users had less complication. At a median follow-up of 365 (323-386) days, the Kaplan-Meier estimate of arrhythmia-free survival was 74% (80% for paroxysmal and 66% for persistent AF). Freedom from arrhythmia was not influenced by operator experience. In 149 (12%) patients, a repeat procedure was performed due to AF recurrence and 418/584 (72%) PVs were durably isolated.CONCLUSION: The EU-PORIA registry demonstrates a high single-procedure success rate with an excellent safety profile and short procedure times in a real-world, all-comer AF patient population.
KW - Humans
KW - Male
KW - Middle Aged
KW - Aged
KW - Female
KW - Atrial Fibrillation/diagnosis
KW - Poria
KW - Treatment Outcome
KW - Catheter Ablation/adverse effects
KW - Fluoroscopy
KW - Pulmonary Veins/surgery
KW - Recurrence
UR - http://www.scopus.com/inward/record.url?scp=85169906816&partnerID=8YFLogxK
U2 - 10.1093/europace/euad185
DO - 10.1093/europace/euad185
M3 - Journal article
C2 - 37379528
SN - 1099-5129
VL - 25
SP - 1
EP - 11
JO - Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
JF - Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
IS - 7
ER -