Epidural blood flow and regression of sensory analgesia during continuous postoperative epidural infusion of bupivacaine.

Publikation: Bidrag til tidsskriftTidsskriftartikelForskning

  1. Acute Kidney Injury and Risk of Death After Elective Surgery: Prospective Analysis of Data From an International Cohort Study

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Ketamine as a Rapid Sequence Induction Agent in the Trauma Population: A Systematic Review

    Publikation: Bidrag til tidsskriftReviewForskningpeer review

  3. Anesthesia in Enhanced Recovery Pathways for Hip and Knee Arthroplasty: Where Is the Evidence?

    Publikation: Bidrag til tidsskriftKommentar/debatForskningpeer review

  4. Enhanced Recovery Pathways: Looking Into the Future

    Publikation: Bidrag til tidsskriftLederForskningpeer review

  1. Effects of transjugular intrahepatic portosystemic shunt (TIPS) on blood volume distribution in patients with cirrhosis

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. The Royal Free Hospital Cirrhosis Glomerular Filtration Rate: Validation in a Danish Cohort

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Red blood cell sodium transport in patients with cirrhosis

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer
Epidural blood flow was measured in seven patients undergoing elective abdominal surgery during combined lumbar epidural and general anesthesia. After an initial dose of 20 ml plain bupivacaine 0.5%, a continuous epidural infusion of bupivacaine 0.5% (8 ml/hr) was given for 16 hours for postoperative pain relief. The epidural blood flow was measured by a local 133Xe clearance technique in which 15-35 MBq 133Xe diluted in 1 ml saline was injected through the epidural catheter on the day before surgery (no bupivacaine), 30 minutes after the initial dose of bupivacaine on the morning before surgery, and 8, 12, and 16 hours later during the continuous infusion. Initial blood flow was 6.0 +/- 0.7 ml/min per 100 g tissue (mean +/- SEM). After epidural bupivacaine, blood flow increased in all seven patients to 7.4 +/- 0.7 ml (P less than 0.02). Initial level of sensory analgesia was T4.5 +/- 0.17 (mean +/- SEM). Postoperatively, two patients maintained the initial level of sensory analgesia and low pain score throughout the 16-hour study. In these two patients epidural blood flow remained constant after the initial increase. Flow increased further to 10.3 +/- 0.8 ml/min per 100 g tissue (P less than 0.03) in the other five patients as the level of sensory analgesia regressed postoperatively. These data suggest that changes in epidural blood flow during continuous epidural infusion of bupivacaine, and thus changes in rates of vascular absorption of bupivacaine from the epidural space, may be an important factor contributing to differences in rates of regression of sensory analgesia.
Bidragets oversatte titelEpidural blood flow and regression of sensory analgesia during continuous postoperative epidural infusion of bupivacaine.