Elbow joint kinematics after excision of the radial head

Steen Lund Jensen, Bo Sanderhoff Olsen, Jens Ole Søjbjerg

93 Citationer (Scopus)

Abstract

The contribution of the radial head to elbow joint kinematics was studied in 7 osteoligamentous elbow preparations. During unloaded flexion and extension, radial head excision induced a maximum varus displacement of 1.6 degrees with 20 degrees of joint flexion and a maximum external rotation of 3.2 degrees at 110 degrees of flexion. With application of a 0.75-Nm load, radial head excision induced a maximum laxity of 3.3 degrees at 20 degrees of flexion in forced varus and a maximum laxity of 8.9 degrees at 10 degrees of flexion in forced external rotation. No laxity was observed in forced valgus or internal rotation. The results were independent of the rotation of the forearm. This study indicates that the radial head acts as stabilizer to the elbow joint in forced varus and in forced external rotation. The results suggest that fractures of the radial head cannot be treated by simple excision without altering the basic kinematics of the elbow joint.

OriginalsprogEngelsk
TidsskriftJournal of Shoulder and Elbow Surgery
Vol/bind8
Udgave nummer3
Sider (fra-til)238-41
Antal sider4
ISSN1058-2746
StatusUdgivet - 2 jul. 1999

Fingeraftryk

Dyk ned i forskningsemnerne om 'Elbow joint kinematics after excision of the radial head'. Sammen danner de et unikt fingeraftryk.

Citationsformater