Forskning
Udskriv Udskriv
Switch language
Region Hovedstaden - en del af Københavns Universitetshospital
Udgivet

Duplex ultrasound for identifying renal artery stenosis: direct criteria re-evaluated

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. Tattoo complications and magnetic resonance imaging: a comprehensive review of the literature

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. High versus standard magnetic resonance image resolution of the cervical spine in patients with axial spondyloarthritis

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Grading lumbar disc degeneration: a comparison between low- and high-field MRI

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. New Section Editor: Chest Imaging

    Publikation: Bidrag til tidsskriftTidsskriftartikelFormidling

  5. New section editor: Abdominal and Gastrointestinal Radiology

    Publikation: Bidrag til tidsskriftTidsskriftartikelFormidling

  1. Gastrointestinal Applications of Iodine Quantification Using Dual-Energy CT: A Systematic Review

    Publikation: Bidrag til tidsskriftReviewForskningpeer review

  2. Flow Complexity Estimation in Dysfunctional Arteriovenous Dialysis Fistulas using Vector Flow Imaging

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Postembolization Syndrome after Prostatic Artery Embolization: A Systematic Review

    Publikation: Bidrag til tidsskriftReviewForskningpeer review

  • Karin Zachrisson
  • Hans Herlitz
  • Lars Lönn
  • Mårten Falkenberg
  • Hampus Eklöf
Vis graf over relationer

BACKGROUND: Renal artery duplex ultrasound (RADUS) is an established method for diagnosis of renal artery stenosis (RAS), but there is no consensus regarding optimal RADUS criteria.

PURPOSE: To define optimal cutoff values for RADUS parameters when screening for RAS using intra-arterial trans-stenotic pressure gradient measurement (PGM) as reference.

MATERIAL AND METHODS: The renal arteries of 58 consecutive patients evaluated for renovascular hypertension were examined by RADUS and PGM. Conclusive measurements with both methods were obtained in 76 arteries. Hemodynamically significant RAS was defined as PGM ≥15 mmHg and was found in 43 of the 76 arteries. RADUS parameters included renal artery peak systolic velocity (PSV) and the renal-aortic ratio (RAR) of flow velocities. Receiver operating characteristic curves (ROCs) and Youden's index were used to calculate optimal RADUS criteria for RAS.

RESULTS: When traditional RADUS criteria for RAS were used, with a combination of PSV ≥180 cm/s and RAR ≥3.5, the sensitivity was 62% and the specificity was 91%. When RADUS criteria were optimized for sensitivity, then RAR ≥2.6 alone resulted in a sensitivity of 89% and a specificity of 69%.

CONCLUSION: The RAR ≥2.6 is a more sensitive criterion than traditional RADUS criteria when screening patients with clinical suspicion of RAS.

OriginalsprogEngelsk
TidsskriftActa Radiologica
Vol/bind58
Udgave nummer2
Sider (fra-til)176-182
ISSN0284-1851
DOI
StatusUdgivet - 2017

ID: 49465074