Forskning
Udskriv Udskriv
Switch language
Region Hovedstaden - en del af Københavns Universitetshospital
Udgivet

Diagnostic accuracy and safety of semirigid thoracoscopy in exudative pleural effusions in Denmark

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Diagnostic Yield of EBUS-TBNA During the Learning Curve

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Efficacy of Endobronchial Ultrasound-Transbronchial Needle Aspiration Virtual-Reality Simulator Training

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. EUS-B-guided Biopsies of Lung Tumors

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Impact of EBUS-TBNA on PET-CT Imaging of Mediastinal Nodes

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Computed tomography of the chest in unilateral pleural effusions: outcome of the British Thoracic Society guideline

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Incidence of malignancy and survival in patients with idiopathic pleuritis

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Endoscopic Ultrasound with Bronchoscope-Guided Fine Needle Aspiration for the Diagnosis of Paraesophageally Located Lung Lesions

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Ensuring Basic Competence in Thoracentesis

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  5. EUS-B-FNA for Diagnosing Liver and Celiac Metastases in Lung Cancer Patients

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer

BACKGROUND: To assess the diagnostic accuracy and the safety of medical thoracoscopy (MT) performed with the semirigid thoracoscope.

METHODS: We retrospectively evaluated patients who underwent MT with semirigid thoracoscope under local anesthesia for unexplained exudative pleural effusion from March 1, 2009 to September 1, 2013 in Denmark.

RESULTS: Sixty-nine patients were retrospectively studied. In 13 patients it was not possible to perform the scheduled MT, in 9 cases due to an insufficient pneumothorax, in 3 due to an insufficient pleural effusion, and in 1 due to a purulent pleuritis. In 56 patients in whom MT was completed, the procedure was diagnostic in 44 cases: malignancy was reported in 26 patients and a benign diagnosis in 18. In the remaining 12 patients a definite diagnosis was not reached, and further testing was required.In an "intention-to-treat analysis" (69 patients in total), the diagnostic accuracy of MT was 63%, the sensitivity for malignancy was 59% [95% confidence interval (CI)=43%-73%], the specificity was 100% (95% CI=86%-100%), and the negative likelihood ratio was 0.41 (95% CI=0.29-0.58). Considering the 56 patients in whom it was possible to complete the procedure, the diagnostic accuracy was 78%, the sensitivity for malignancy was 74% (95% CI=54%-87%), the specificity was 100% (95% CI=83.75%-100%), and the negative likelihood ratio was 0.27 (95% CI=0.15%-0.45%). No mortality was reported.

CONCLUSIONS: MT performed under local anesthesia with a semirigid scope is a simple and safe procedure with an acceptable sensitivity for malignancy.

OriginalsprogEngelsk
TidsskriftJournal of Bronchology & Interventional Pulmonology
Vol/bind21
Udgave nummer3
Sider (fra-til)215-9
Antal sider5
ISSN1944-6586
DOI
StatusUdgivet - jul. 2014

ID: 44999700