Forskning
Udskriv Udskriv
Switch language
Region Hovedstaden - en del af Københavns Universitetshospital
Udgivet

Determination and validation of peak fat oxidation in endurance-trained men using an upper body graded exercise test

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. Cardiovascular and metabolic health effects of team handball training in overweight women: Impact of prior experience

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Influence of between-limb asymmetry in muscle mass, strength, and power on functional capacity in healthy older adults

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Physical activity during pregnancy and intelligence in sons; A cohort study

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. High-Volume Injection with and without Corticosteroid in Chronic Midportion Achilles Tendinopathy

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  5. In-season adaptations to intense intermittent training and sprint interval training in sub-elite football players

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Acetaminophen toxicity induces mitochondrial complex I inhibition in human liver tissue

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Mitochondrial adaptations to high intensity interval training in older females and males

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  • Mikkel Thunestvedt Hansen
  • Tue Rømer
  • Jacob Frandsen
  • Steen Larsen
  • Flemming Dela
  • Jørn Wulff Helge
Vis graf over relationer

Peak fat oxidation rate (PFO) and the intensity that elicits PFO (Fatmax ) are commonly determined by a validated graded exercise test (GE) on a cycling ergometer with indirect calorimetry. However, for upper body exercise fat oxidation rates are not well elucidated and no protocol has been validated. Thus, our aim was to test validity and inter-method reliability for determination of PFO and Fatmax in trained men using a GE protocol applying double poling on a ski-ergometer. PFO and Fatmax were assessed during two identical GE tests (GE1 and GE2) and validated against separated short continuous exercise bouts (SCE) at 35%, 50%, and 65% of V̇O2peak on the ski-ergometer in 10 endurance-trained men (V̇O2peak : 65.1 ± 1.0 mL·min-1 ·kg-1 , mean ± SEM). Between GE tests no differences were found in PFO (GE1: 0.42 ± 0.03; GE2: 0.45 ± 0.03 g·min-1 , P = .256) or Fatmax (GE1: 41 ± 2%; GE2: 43 ± 3% of V̇O2peak , P = .457) and the intra-individual coefficient of variation (CV) was 8 ± 2% and 11 ± 2% for PFO and Fatmax , respectively. Between GE and SCE tests, PFO (GEavg : 0.44 ± 0.03; SCE; 0.47 ± 0.06 g·min-1 , P = .510) was not different, whereas a difference in Fatmax (GEavg : 42 ± 2%; SCE: 52 ± 4% of V̇O2peak , P = .030) was observed with a CV of 17 ± 4% and 15 ± 4% for PFO and Fatmax , respectively. In conclusion, GE has a high day-to-day reliability in determination of PFO and Fatmax in trained men, whereas it is unclear if PFO and Fatmax determined by GE reflect continuous exercise in general.

OriginalsprogEngelsk
TidsskriftScandinavian journal of medicine & science in sports
Vol/bind29
Udgave nummer11
Sider (fra-til)1677-1690
Antal sider14
ISSN0905-7188
DOI
StatusUdgivet - nov. 2019

Bibliografisk note

© 2019 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

ID: 59397878