Forskning
Udskriv Udskriv
Switch language
Region Hovedstaden - en del af Københavns Universitetshospital
Udgivet

Detection of atrial fibrillation with implantable loop recorders in horses

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. Advances in the understanding of tendinopathies: a report on the Second Havemeyer Workshop on equine tendon disease

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Symptoms Preceding Sports-Related Sudden Cardiac Death in Persons Aged 1-49 Years

    Publikation: Bidrag til tidsskriftReviewForskningpeer review

  2. Symptoms and healthcare contact preceding sudden cardiac death in persons aged 1-49 years

    Publikation: Bidrag til tidsskriftReviewForskningpeer review

  3. Common and rare susceptibility genetic variants predisposing to Brugada syndrome in Thailand

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  • Rikke Buhl
  • Eva M Hesselkilde
  • Helena Carstensen
  • Merle F Fenner
  • Thomas Jespersen
  • Jacob Tfelt-Hansen
  • Stefan Michael Sattler
Vis graf over relationer

BACKGROUND: Cardiac arrhythmias in horses are diagnosed by auscultation or electrocardiogram (ECG), which results in a low sensitivity for detecting arrhythmias that occur sporadically. Implantable loop recorders (ILRs) are small ECG devices placed subcutaneously, to automatically detect arrhythmias in human patients.

OBJECTIVES: To test ILRs ability to detect atrial fibrillation (AF) in horses. Furthermore, we hypothesised that anatomical location of the implant site might influence signal quality. Signal quality was evaluated both during exercise and over time.

STUDY DESIGN: Experimental study.

METHODS: In five Standardbred mares, eleven ILRs were implanted subcutaneously in up to three different positions (Front: pectoral region, Left-6: sixth left intercostal space and Ventral: xiphoid region) and AF induced. The R- and T-wave amplitudes were measured in all positions over time during AF. AF burden automatically registered by the ILRs over a 2-month period was compared with selected Holter ECG recordings.

RESULTS: All three positions had stable R- and T-wave amplitudes during the study period and were of sufficient quality to allow AF detection at rest. The position Left-6 showed significantly higher R- and T-wave amplitudes compared with the other positions. During submaximal exercise only the Left-6 position was able to record ECG signals of diagnostic quality. No position yielded diagnostic signals at maximum exercise due to artefacts.

MAIN LIMITATIONS: Few horses and ILRs included and no spontaneous AF episodes were studied.

CONCLUSIONS: This preliminary study indicates that ILRs can be used for AF detection in horses, but the anatomical location is important for optimal ECG quality. Despite insufficient quality during exercise, ILRs were suitable for AF detection at rest. Therefore, the ILR may be a valuable diagnostic tool for detecting paroxysmal AF in horses.