Cuff inflations do not affect night-time blood pressure: comparison of 24 h ambulatory blood pressure measured by a cuff and a tonometric device in type 2 diabetes

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Home blood pressure in pregnancy-the upper reference limit

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Self-monitoring of blood pressure during pregnancy: an observational study in the obstetrical waiting room

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Spontaneous blood pressure oscillations in mechanically ventilated patients with sepsis

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. From pioneering to implementing automated blood pressure measurement in clinical practice: Thomas Pickering's legacy

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Relation of cardiac adipose tissue to coronary calcification and myocardial microvascular function in type 1 and type 2 diabetes

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Describing the fecal metabolome in cryogenically collected samples from healthy participants

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Carotid-femoral pulse wave velocity is a risk marker for complications in persons with type 1 diabetes

    Publikation: KonferencebidragKonferenceabstrakt til konferenceForskning

Vis graf over relationer

Discomfort related to cuff inflation may bias 24 h ambulatory blood pressure (BP) measurements, especially during night-time. We accessed the impact of cuff inflations by comparing 24 h BP recorded with a cuff-less tonometric wrist device and an upper-arm oscillometric cuff device. Fifty-three participants with type 2 diabetes were assigned randomly to four 24-h BP recordings with a cuff (TM2430: visit 1 or 2, and 4) and a tonometric device (BPro: visit 1 or 2, 3, and 4). The mean 24 h systolic BP was significantly higher when measured with the cuff versus the tonometric device (141.6±14.6 vs. 128.3±14.6 mmHg, P≤0.01), as was nocturnal BP (6.7±5.3 vs. 10.3±7.6%, P=0.002). In conclusion, nocturnal BP decline was higher when measured with the cuff device, suggesting that cuff inflations did not increase night-time BP. Further evaluation of the tonometric device using the updated European Society of Hypertension International Protocol revision 2010 is recommended before applying it in daily clinical practice.

OriginalsprogEngelsk
TidsskriftBlood Pressure Monitoring
Vol/bind20
Udgave nummer6
Sider (fra-til)369-72
Antal sider4
ISSN1359-5237
DOI
StatusUdgivet - dec. 2015
Eksternt udgivetJa

ID: 51477711