@article{6bd98dcfadcb458bab1ec064ea8c121a,
title = "Constrained liners for recurrent dislocations in total hip arthroplasty",
abstract = "This study reports the results and complications from treating recurrent hip dislocations with a constrained liner (CL) after total hip arthroplasty (THA). Forty patients who had a CL inserted as a secondary prophylactic treatment were retrospectively reviewed after a median observation period of 27 months (range 7-77 months). During the observation period five patients had to be revised: one for deep infection and four on account of re-dislocations. Our results indicate that patients with recurrent THA dislocations can be treated with a CL and has a satisfactory low complication rate and a relatively low risk of re-dislocation.",
author = "R Knudsen and O Ovesen and P Kjaersgaard-Andersen and S Overgaard",
year = "2009",
language = "English",
volume = "17",
pages = "78--81",
journal = "HIP International",
issn = "1120-7000",
publisher = "Wichtig Publishing",
number = "2",
}