Comparison of Continuous Glucose Monitoring Accuracy Between Abdominal and Upper Arm Insertion Sites

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. Glucose Sensor Accuracy After Subcutaneous Glucagon Injections Near to Sensor Site

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Skin Problems Due to Treatment with Technology Are Associated with Increased Disease Burden Among Adults with Type 1 Diabetes

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. DIWHY – Motivations, barriers and retention factors of DIY artificial pancreas users in real world use

    Publikation: Bidrag til tidsskriftKonferenceabstrakt i tidsskriftForskningpeer review

  1. Newborn body composition after maternal bariatric surgery

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Glycaemic variability and hypoglycaemia are associated with C-peptide levels in insulin-treated type 2 diabetes

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Psychosocial factors and HbA1c in people with insulin-pump treated type 1 diabetes: Protocol for an ongoing systematic literature review

    Publikation: KonferencebidragKonferenceabstrakt til konferenceForskningpeer review

  4. Glucose Sensor Accuracy After Subcutaneous Glucagon Injections Near to Sensor Site

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer

Background: The aim was to compare the accuracy of the Dexcom® G4 Platinum continuous glucose monitor (CGM) sensor inserted on the upper arm and the abdomen in adults. Methods: Fourteen adults with type 1 diabetes wore two CGMs, one placed on the upper arm and one placed on the abdomen. Three in-clinic visits of 5 h with YSI (2300 STAT, Yellow Springs Instrument) measurements as comparator were performed. Each visit was followed by 4 days with seven-point self-monitoring of blood glucose (SMBG) in free-living conditions. Accuracy analyses on the paired CGM-YSI and CGM-SMBG measurements of the two CGM sensors were performed. Results: Using YSI as comparator, the overall Mean Absolute Relative Difference (MARD) for the CGMabd was 12.3% and CGMarm was 12.0%. The percentage of the CGM measurements in zone A of Clarke error grid analysis for the CGMabd was 85.6% and CGMarm was 86.0%. The hypoglycemia sensitivity for the CGMabd and CGMarm was 69.3%. Using SMBG as comparator, the overall MARD for the CGMabd was 12.5% and CGMarm was 12.0%. The percentage of the CGM measurements in zone A for the CGMabd was 84.1% and the CGMarm was 85.0%. The hypoglycemia sensitivity for the CGMabd was 60.0% and the CGMarm was 71.1%. All the P-values from the comparisons between the accuracy of CGMabd and CGMarm were >0.05. Conclusion: The accuracy of a Dexcom G4 Platinum CGM sensor placed on the upper arm was not different from the accuracy of the sensor placed on the abdomen in adults with type 1 diabetes.

OriginalsprogEngelsk
TidsskriftDiabetes Technology and Therapeutics
Vol/bind21
Udgave nummer5
Sider (fra-til)295-302
Antal sider8
ISSN1520-9156
DOI
StatusUdgivet - 1 maj 2019

ID: 57015210