Forskning
Udskriv Udskriv
Switch language
Region Hovedstaden - en del af Københavns Universitetshospital
Udgivet

Comparison of a novel porous titanium construct (Regenerex®) to a well proven porous coated tibial surface in cementless total knee arthroplasty - A prospective randomized RSA study with two-year follow-up

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

DOI

  1. Knee extensor strength and hop test performance following anterior cruciate ligament reconstruction

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. A comparison of hamstring muscle activity during different screening tests for non-contact ACL injury

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. The risk of manipulation under anesthesia due to unsatisfactory knee flexion after fast-track total knee arthroplasty

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Incidence of surgical interventions for metastatic bone disease in the extremities: a population-based cohort study

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Treatment of benign and borderline bone tumors with combined curettage and bone defect reconstruction

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Bone Remodeling of the Distal Femur After Uncemented Total Knee Arthroplasty-A 2-Year Prospective DXA Study

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Comparison of two alternative wound closure methods for tumor arthroplasty of the hip: A frequency matched cohort study

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer

BACKGROUND: Regenerex is a novel porous titanium construct with a three-dimensional porous structure and biomechanical characteristics close to that of normal trabecular bone. The aim of this study was to compare this novel construct to a well-proven porous plasma sprayed tibial (PPS) implant after total knee arthroplasty.

METHODS: Sixty-one patients scheduled for an uncemented TKA were randomized to receive either a novel highly porous titanium construct Regenerex or the PPS tibial component. Radiostereometric analysis of the tibial components was performed postoperatively and at three, six, 12, and 24months with measurements of migration (segment motion and maximum total point motion (MTPM)).

RESULTS: Knee and function scores improved significantly from preoperatively to two-year follow-up. For both the Regenerex and the PPS the majority of migration appeared during the first three months and then stabilized. No statistically significant differences in MTPM were found in any follow-up between three and 24months. The Regenerex group had a lower migration rate between 12 and 24months compared with the PPS implants (p=0.03) but the PPS group had an initial significantly lower subsidence (p=0.04).

CONCLUSION: In conclusion the Regenerex implant could prove an effective scaffold material for coating of uncemented implants but did no better than the PPS component at 24months of follow-up. ClinicalTrials.gov identifier: NCT01936415.