Common Carotid Artery Flow Measured by 3-D Ultrasonic Vector Flow Imaging and Validated with Magnetic Resonance Imaging

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Full-Volume Assessment of Abdominal Aortic Aneurysms by 3-D Ultrasound and Magnetic Tracking

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Contrast-Enhanced Ultrasound: Development of Syllabus for Core Theoretical and Practical Competencies

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Flow Complexity Estimation in Dysfunctional Arteriovenous Dialysis Fistulas using Vector Flow Imaging

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  4. Commentary on the World Federation for Ultrasound in Medicine and Biology Project "Incidental Findings"

    Publikation: Bidrag til tidsskriftKommentar/debatForskningpeer review

  1. Gastrointestinal Applications of Iodine Quantification Using Dual-Energy CT: A Systematic Review

    Publikation: Bidrag til tidsskriftReviewForskningpeer review

  2. Evaluation of inflammatory lesions over 2 years in facioscapulohumeral muscular dystrophy

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. Flow Complexity Estimation in Dysfunctional Arteriovenous Dialysis Fistulas using Vector Flow Imaging

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer

Ultrasound (US) examination of the common carotid artery was compared with a through-plane magnetic resonance imaging (MRI) sequence to validate a recently proposed technique for 3-D US vector flow imaging. Data from the first volunteer examined were used as the training set, before volume flow and peak velocities were calculated for the remaining eight volunteers. Peak systolic velocities (PSVs) and volume flow obtained with 3-D US were, on average, 34% higher and 24% lower than those obtained with MRI, respectively. A high correlation was observed for PSV (r = 0.79), whereas a lower correlation was observed for volume flow (r = 0.43). The overall standard deviations were ±5.7% and ±5.7% for volume flow and PSV with 3-D US, compared with ±2.7% and ±3.2% for MRI. Finally, the data were re-processed with a change in the parameter settings for the echo-canceling filter to investigate its influence on overall performance. PSV was less affected by the re-processing, whereas the difference in volume flow between 3-D vector flow imaging and MRI was reduced to -9%, and with an improved overall standard deviation of ±4.7%. The results illustrate the feasibility of using 3-D US for precise and angle-independent volume flow and PSV estimation in vivo.

OriginalsprogEngelsk
TidsskriftUltrasound in Medicine and Biology
Vol/bind43
Udgave nummer10
Sider (fra-til)2213-2220
Antal sider8
ISSN0301-5629
DOI
StatusUdgivet - okt. 2017

ID: 52105003