Abstract
AIMS: It is well known that endoscopic ultrasound guided fine needle aspiration (EUS-FNA) has a high sensitivity (over 85%) and specificity (100%) for diagnosis of pancreatic cancer. The aim of the study was to establish a EUS based clinical diagnostic algorithm in patients with pancreatic masses and negative cytopathology after EUS-FNA, based on previously published results and cut-offs of real-time elastographic (RTE) EUS and contrast-enhanced harmonic (CEH) EUS.
MATERIAL AND METHODS: We included in the study a subgroup of 50 consecutive patients with focal pancreatic masses which underwent EUS examinations with negative EUS-FNA. RTE-EUS and CEH-EUS were performed sequentially in all patients. The sensitivity, specificity and accuracy of these methods were calculated separately. A clinical decision algorithm based on elastography followed by CEH was established.
RESULTS: For the diagnosis of possible malignancy, the sensitivity, specificity and accuracy of RTE-EUS were: 97.7%, 77.4%, and 84% respectively. CEH-EUS had similar results: 89.5%, 80.7%, and 84%, respectively. In 25 patients with soft/mixed appearance during elastography,sequential assessment using contrast-enhanced EUSwas performed. The specificity of CEH-EUS for detection of chronic pancreatitis in this sub-set of patients was excellent (100%). In other 25 patients with hard appearance in elastography (low strain) CEH-EUS had an excellent specificity (100%) and accuracy (93%) in the detection of pancreatic cancer.
CONCLUSIONS: The proposed algorithm with sequential use of elastography followed by CEH could be a good clinical tool in the set of patients with negative EUS-FNA results for the differentiation between benign and malignant focal pancreatic masses.
Originalsprog | Engelsk |
---|---|
Tidsskrift | Medical Ultrasonography |
Vol/bind | 18 |
Udgave nummer | 1 |
Sider (fra-til) | 18-24 |
Antal sider | 7 |
ISSN | 1844-4172 |
Status | Udgivet - mar. 2016 |