Forskning
Udskriv Udskriv
Switch language
Region Hovedstaden - en del af Københavns Universitetshospital
Udgivet

CIED infection with either pocket or systemic infection presentation - complete device removal and long-term antibiotic treatment; long-term outcome

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Relationship Between Invasive Hemodynamics and Liver Function in Advanced Heart Failure

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Atrial fibrillation and anticoagulation in patients with breast cancer

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  3. A national needs assessment study to determine procedures for simulation-based training in cardiology in Denmark

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  1. Coronary risk of patients with valvular heart disease: prospective validation of CT-Valve Score

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

  2. Differences in mortality in patients undergoing surgery for infective endocarditis according to age and valvular surgery

    Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Vis graf over relationer

OBJECTIVE: Cardiovascular implantable electronic device (CIED) infections are increasing in numbers. The objective was to review the clinical presentation and outcome in patients affected with CIED infections with either local pocket or systemic presentation.

DESIGN: All device removals due to CIED infection during the period from 2005 to 2012 were retrospectively reviewed. CIED infections were categorized as systemic or pocket infections. Treatment included complete removal of the device, followed by antibiotic treatment of six weeks.

RESULTS: Seventy-one device removals due to infection (32 systemic and 39 pocket infections) were recorded during the study period. Median follow-up time was 26 (IQR 9-41) months, 30 day and 12 month mortality were 4% and 14%, respectively. There was no long-term difference in mortality between patients with pocket vs. systemic infection (p = 0.48). During follow-up no relapses and two cases of new infections were noted (2.8%).

CONCLUSIONS: CIED infection with systemic or pocket infection was difficult to distinguish in clinical presentation and outcome. Complete device removal and antibiotic treatment of long duration was safe and without relapses.