Spring til hovednavigation Spring til søgning Spring til hovedindhold

Can varying flow velocity across an arterial anastomosis prevent thromboembolic injury?

  • J H Barker
  • , D M Andresen
  • , G L Anderson
  • , D Schuschke
  • , J M Gu
  • , S Gupta
  • , V E Hjortdal
  • , J W Derr
  • , J C Banis
  • , R D Acland
8 Citationer (Scopus)

Abstract

In this study, simulated "poor" repairs applied to transverse incisions in the iliac arteries of 40 rats were the basis for comparing the effect of variations in blood flow on thromboembolism. Using vital microscopy and digital image processing, we performed 2 experiments. In the first experiment (n = 20), the reduction of post-repair blood flow by approximately 50% resulted in an 83% reduction in the total number of emboli appearing in the microcirculation of the cremaster muscle distal to the repair. In the second experiment (n = 20), the same reduction in blood flow typically resulted in larger repair-site thrombi which required significantly more time to grow to their maximum size. We conclude that reducing pedicle artery blood flow to approximately half in our rat model during reperfusion can protect the downstream microcirculation from embolic injury without increasing the incidence of thrombotic occlusion.

OriginalsprogEngelsk
TidsskriftMicrosurgery
Vol/bind16
Udgave nummer5
Sider (fra-til)349-56
Antal sider8
ISSN0738-1085
DOI
StatusUdgivet - 1995
Udgivet eksterntJa

Fingeraftryk

Dyk ned i forskningsemnerne om 'Can varying flow velocity across an arterial anastomosis prevent thromboembolic injury?'. Sammen danner de et unikt fingeraftryk.

Citationsformater